4.7 Article

A Radiographic Analysis of Proximal Humeral Anatomy in Patients with Primary Glenohumeral Arthritis and Implications for Press-Fit Stem Length

Journal

JOURNAL OF CLINICAL MEDICINE
Volume 11, Issue 10, Pages -

Publisher

MDPI
DOI: 10.3390/jcm11102867

Keywords

total shoulder arthroplasty; glenohumeral arthritis; humeral stem; arthroplasty; stem length; shoulder replacement

Ask authors/readers for more resources

This study analyzed the intramedullary canal in TSA patients and found a transition point at 73mm distal to the greater tuberosity, indicating that a 90mm stem length is required for predictably reaching a consistent and cylindrical humeral canal diameter.
While short stems in total shoulder arthroplasty (TSA) preserve bone stock and facilitate revision surgery, they have been associated with higher rates of malalignment and loosening in some cases compared to standard length stems. The purpose of this study was to analyze the intramedullary canal in progressive increments distal to the greater tuberosity to provide anatomic information about the optimal length of press-fit short stems for alignment and stability in TSA. We hypothesized that the humeral canal diameter will remain variable for the first 50 to 75 mm distal to the greater tuberosity and will become consistent thereafter. A retrospective review of 99 consecutive patients undergoing TSA with CT scans was performed. Intramedullary anterior-posterior (AP) and medial-lateral (ML) width as well as diameter were analyzed on two-dimensional computed tomography following multiplanar reconstruction. Measurements were taken at consistent distances distal to the greater tuberosity (GT). The transition point was measured at the proximal level of the humerus where endosteal borders of the medial and lateral cortices became parallel. The mean transition point was 73 mm from the GT (range: 53 to 109 mm). ML and AP widths became consistent 80 mm distal to the GT. IM diameter became consistent after 90 mm distal to the GT and a stem length of 90 mm extended past the transition point in 91.9% of cases. In TSA, a humeral stem length of 90 mm is required to predictably reach points at which the humeral canal becomes cylindrical and consistent in diameter. This information may aid data-driven decisions on humeral stem length during press-fit fixation, assuring consistency of alignment and implant stability, while maintaining ease of revision associated with a short stem implant. Level of evidence: III

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available