4.5 Article

Comparison between 1.5-T and 3.0-T MRI for the diagnosis of placenta accreta spectrum disorders

Journal

DIAGNOSTIC AND INTERVENTIONAL IMAGING
Volume 103, Issue 9, Pages 408-417

Publisher

ELSEVIER MASSON, CORP OFF
DOI: 10.1016/j.diii.2022.04.005

Keywords

Placenta accreta spectrum; Invasive placenta; Placenta accreta; Pregnancy; Magnetic resonance imaging

Ask authors/readers for more resources

This study compared the diagnostic capabilities of 1.5-T and 3.0-T MRI in placenta accreta spectrum (PAS) and found that both imaging techniques have equivalent effectiveness. MRI showed high sensitivity and specificity for PAS diagnosis and accurately predicted extrauterine placental spread.
Purpose: Accurate antenatal diagnosis of placenta accreta spectrum (PAS) is important for optimal management. The purpose of this study was to compare the respective capabilities of 1.5-T and 3.0-T MRI in the diagnosis of PAS. Materials and methods: Between March 2016-March 2021, 190 pregnant women at high risk for PAS underwent dedicated prenatal MRI with either 1.5-T or 3.0-T units at a tertiary imaging center. Cesarian section and MRI were performed less than 6 weeks from each other. Prospectively collected data were evaluated by two experienced genitourinary radiologists for presence and extent of PAS. A comparative study was designed to investigate differences in predictive ability between 1.5-T and 3.0-T MRI groups. Sensitivity, specificity, accuracy, negative and positive prognostic values relative to intraoperative/histological findings, were computed for both groups and were compared with chi-square (chi 2) test. Interobserver agreement was estimated using Kappa test. Results: One hundred-eighty-two gravid women were included in the study; of these, 91/182 (50%) women were evaluated with 1.5-T (mean age, 35 +/- 5.1 [SD] years; mean gestational age: 32.5 weeks) and 91/182 (50%) with 3.0-T MRI (mean age, 34.9 +/- 4.9 [SD] years; mean gestational age, 32.1 weeks). 1.5-T MRI yielded 95.7% sensitivity (95% CI: 87.8-99.1) and 81.8% specificity (95% CI: 59.8) and 3.0-T MRI 93.8% sensitivity (95% CI: 86.0-97.9) and 83.3% specificity (95% CI: 48.2-97.7) for PAS identification, with no differences between the two groups (P = 0.725 and P > 0.999, respectively). MRI showed excellent predictive ability for detecting extrauterine placental spread with 100% sensitivity (95% CI: 89.4-100.0), 96.7% specificity (95% CI: 88.1-99.6) for 1.5-T and 97% sensitivity (95% CI: 84.2-99.9), 96.7% specificity (95% CI: 88.1-99.6) for 3.0-T without differences between the two groups (P > 0.999). Interobserver agreement was excellent for both groups. The most frequently detected MRI signs of PAS for both 1.5-T and 3.0-T groups were placental heterogeneity (n = 85, 93.5% vs. n = 90, 98.9%; P = 0.413), and intraplacental fetal vessels (n = 64, 70.3% vs. n = 65, 71.4%; P = 0.870). Conclusion: This study suggests that 3.0-T MRI and 1.5-T MRI are equivalent for the diagnosis of PAS. (C) 2022 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available