4.7 Article

Analysis of the Effect of Electrode Materials on the Sensitivity of Quartz Crystal Microbalance

Related references

Note: Only part of the references are listed.
Article Nanoscience & Nanotechnology

Phenyl-Modified Carbon Nitride Quantum Nanoflakes for Ultra-Highly Selective Sensing of Formic Acid: A Combined Experimental by QCM and Density Functional Theory Study

Nagy L. Torad et al.

Summary: This study introduces a chemical sensor based on a QCM sensor capable of rapidly detecting trace amounts of formic acid. The sensor, prepared using a facile solid-state method, exhibits enhanced detection sensitivity and selectivity for formic acid, with a detection limit down to sub-ppm levels. The sensing technology based on phenyl-terminated attached-g-C3N4 nanoflakes provides a simple and low-cost solution for effectively discriminating formic acid vapors using smart electronic noses.

ACS APPLIED MATERIALS & INTERFACES (2021)

Article Chemistry, Analytical

Analysis of the Uniformization of the QCM Mass Sensitivity Distribution through a Dot Multiring Electrode Structure

Wei Pan et al.

Summary: This study theoretically analyzes the impact of different sizes of dot ring and dot double-ring electrodes on the mass sensitivity distribution of the quartz crystal microbalance (QCM), and proposes a dot triple-ring electrode to enhance uniformity. The research provides a new direction for improving the uniformization of QCM mass sensitivity distribution.

ANALYTICAL CHEMISTRY (2021)

Article Engineering, Electrical & Electronic

Ringed Electrode Configuration Enhances the Sensitivity of QCM Humidity Sensor Based on Lignin Through Fringing Field Effect

Qiao Chen et al.

Summary: This study introduces a novel method to enhance the humidity sensitivity of lignin-based QCM sensor through fringing field effect, showing that the ringed electrode configuration provides higher sensitivity and better performance.

IEEE SENSORS JOURNAL (2021)

Article Chemistry, Analytical

Label-Free Protein Analysis Using Liquid Chromatography with Gravimetric Detection

Tadas Kartanas et al.

Summary: The article discusses a strategy that overcomes the limitation of lack of analyte selectivity in label-free protein analysis by coupling liquid chromatography with a quartz crystal microbalance (QCM) platform using a microfluidic spray dryer. This strategy enables quantitative label-free analysis of protein mixtures and offers the potential for detection of protein species under physiological conditions.

ANALYTICAL CHEMISTRY (2021)

Article Chemistry, Physical

Ultra-highly sensitive humidity sensing by polydopamine/graphene oxide nanostructure on quartz crystal microbalance

Dongzhi Zhang et al.

Summary: This study presents a solution for high-performance humidity sensors by coating PDA-GO nanocomposite films on quartz crystal microbalances. The sensors exhibit best dynamic response with specific ratio and spray amount, fast response/recovery time, stable repeatability, and excellent stability, showing potential in various applications.

APPLIED SURFACE SCIENCE (2021)

Article Acoustics

The Effect of Electrode Thickness on Mass Sensitivity of QCM Cannot Be Ignored

Xianhe Huang et al.

Summary: The accuracy of mass sensitivity value of Quartz crystal microbalance (QCM) greatly affects data analysis and experiment repeatability. Uncertainty in electrode thickness values provided by companies inevitably brings large experimental errors, leading to inaccuracy and poor repeatability of QCM experiments.

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL (2021)

Review Engineering, Electrical & Electronic

Gas and humidity sensing with quartz crystal microbalance (QCM) coated with graphene-based materials-A mini review

Fika Fauzi et al.

Summary: Graphene and graphene-based materials have great potential in detecting gases and humidity due to their high specific surface areas. Recently, QCM sensors coated with graphene composites have been explored for their sensitivity and selectivity in detecting various gases and humidity. Challenges for future works include further development of QCM sensors using graphene materials or composites.

SENSORS AND ACTUATORS A-PHYSICAL (2021)

Article Nanoscience & Nanotechnology

Virtual Sensor Array Based on Butterworth-Van Dyke Equivalent Model of QCM for Selective Detection of Volatile Organic Compounds

Dongsheng Li et al.

Summary: The study introduces a VSA based on QCM and MXene, which enhances the detection of VOCs, accurately identifies and quantifies different VOCs using machine learning algorithms, and can identify patients with diabetic ketosis from exhaled breath with a high accuracy of 95%.

ACS APPLIED MATERIALS & INTERFACES (2021)

Article Chemistry, Analytical

Disaggregation Behavior of Amyloid β Fibrils by Anthocyanins Studied by Total-Internal-Reflection-Fluorescence Microscopy Coupled with a Wireless Quartz-Crystal Microbalance Biosensor

Kentaro Noi et al.

Summary: The disassembly activity of anthocyanins on Aβ fibrils depends on the number of hydroxyl groups in the six-membered ring B of anthocyanin, with only delphinidin-3-galactoside showing high disassembly activity due to possessing three hydroxyl groups there. Results demonstrate the importance of the number of hydroxyl groups and highlight the usefulness of TIRFM-QCM as a powerful tool in studying interactions between amyloid fibrils and compounds.

ANALYTICAL CHEMISTRY (2021)

Review Chemistry, Multidisciplinary

From bulk to interface: electrochemical phenomena and mechanism studies in batteries via electrochemical quartz crystal microbalance

Yuchen Ji et al.

Summary: EQCM technology is a powerful tool for understanding the bulk and interfacial behaviors during battery operation, enabling investigation into phenomena such as ion insertion/deinsertion, solid nucleation, and interphase formation. Recent studies have utilized EQCM to reveal phenomena and mechanisms in various batteries, showing promise for future applications in battery research.

CHEMICAL SOCIETY REVIEWS (2021)

Article Chemistry, Physical

A humidity sensing and respiratory monitoring system constructed from quartz crystal microbalance sensors based on a chitosan/polypyrrole composite film

Xiaohua Liu et al.

Summary: In this study, a QCM humidity sensor based on a CS/PPy composite film was prepared using a simple physical modification method, and the synthesized composite was characterized. The sensor showed high sensitivity, low hysteresis, short response/recovery time, excellent selectivity, and stability, and could accurately sense changes in breathing parameters.

JOURNAL OF MATERIALS CHEMISTRY A (2021)

Review Chemistry, Multidisciplinary

Recent Advances in Graphene-Based Humidity Sensors

Chao Lv et al.

NANOMATERIALS (2019)

Article Chemistry, Analytical

Quartz Crystal Microbalance with Approximately Uniform Sensitivity Distribution

Xianhe Huang et al.

ANALYTICAL CHEMISTRY (2018)

Article Acoustics

The Exploration and Confirmation of the Maximum Mass Sensitivity of Quartz Crystal Microbalance

Xian-He Huang et al.

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL (2018)

Article Engineering, Electrical & Electronic

Quartz Crystal Microbalance Humidity Sensors Based on Nanodiamond Sensing Films

Yao Yao et al.

IEEE TRANSACTIONS ON NANOTECHNOLOGY (2014)

Article Chemistry, Physical

Graphene oxide thin film coated quartz crystal microbalance for humidity detection

Yao Yao et al.

APPLIED SURFACE SCIENCE (2011)

Article Engineering, Electrical & Electronic

Patterned Electrodes for Thickness Shear Mode Quartz Resonators to Achieve Uniform Mass Sensitivity Distribution

Anthony Richardson et al.

IEEE SENSORS JOURNAL (2009)