4.6 Article

An unsupervised learning method to identify reference intervals from a clinical database

Journal

JOURNAL OF BIOMEDICAL INFORMATICS
Volume 59, Issue -, Pages 276-284

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jbi.2015.12.010

Keywords

Laboratory tests; Reference intervals; Unsupervised learning; Electronic health record

Funding

  1. NLM grant [R01 LM011369]
  2. Fulbright New Zealand
  3. J.R. Templin Trust

Ask authors/readers for more resources

Reference intervals are critical for the interpretation of laboratory results. The development of reference intervals using traditional methods is time consuming and costly. An alternative approach, known as an a posteriori method, requires an expert to enumerate diagnoses and procedures that can affect the measurement of interest. We develop a method, LIMIT, to use laboratory test results from a clinical database to identify ICD9 codes that are associated with extreme laboratory results, thus automating the a posteriori method. LIMIT was developed using sodium serum levels, and validated using potassium serum levels, both tests for which harmonized reference intervals already exist. To test LIMIT, reference intervals for total hemoglobin in whole blood were learned, and were compared with the hemoglobin reference intervals found using an existing a posteriori approach. In addition, prescription of iron supplements were used to identify individuals whose hemoglobin levels were low enough for a clinician to choose to take action. This prescription data indicating clinical action was then used to estimate the validity of the hemoglobin reference interval sets. Results show that LIMIT produces usable reference intervals for sodium, potassium and hemoglobin laboratory tests. The hemoglobin intervals produced using the data driven approaches consistently had higher positive predictive value and specificity in predicting an iron supplement prescription than the existing intervals. LIMIT represents a fast and inexpensive solution for calculating reference intervals, and shows that it is possible to use laboratory results and coded diagnoses to learn laboratory test reference intervals from clinical data warehouses. (C) 2015 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available