4.6 Article

Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging

Journal

FRONTIERS IN NEUROSCIENCE
Volume 16, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fnins.2022.844408

Keywords

magnetic resonance imaging; diffusion tensor imaging; single-shot echo-planar imaging; readout-segmented echo-planar imaging; peripheral nerve

Categories

Funding

  1. National Natural Science Foundation of China [81903960]
  2. Natural Science Foundation of Guangdong Province [2020A1515010732]

Ask authors/readers for more resources

This study compared the performances of single-shot echo-planar imaging (SS-EPI) and readout-segmented echo-planar imaging (RS-EPI) for diffusion tensor imaging (DTI) of the rat sciatic nerve, and found that SS-EPI sequence showed significantly higher image quality and correlation coefficients compared with RS-EPI sequence.
ObjectivesTo compare the performances of single-shot echo-planar imaging (SS-EPI) and readout-segmented echo-planar imaging (RS-EPI) for diffusion tensor imaging (DTI) of the rat sciatic nerve. MethodsEight healthy adult male Sprague-Dawley rats were anesthetized and scanned with a 3T MRI scanner using SS-EPI and RS-EPI DTI sequences. The image quality in terms of the morphology of the nerve, distortions of the nearby femur, muscles, and homogeneity of neuromuscular were evaluated and scored. The correlations between the DTI parameters including fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), apparent diffusion coefficient (ADC), and histopathological parameters were calculated by using the Pearson correlation coefficient and compared by the modified Fisher Z-transform, respectively. ResultsThe quality scores were higher for the images from the SS-EPI sequence compared with the RS-EPI sequence for characteristics such as sharpness of the sciatic nerve margin (P = 0.008), artifacts of the sciatic nerve (P = 0.008), and homogeneity of the neuromuscular region (P = 0.007), as well as the contrast-to-noise ratio (CNR) of DW images (P < 0.001). The correlation coefficients were higher for the FA and RD values from the SS-EPI sequence compared with those from the RS-EPI sequence. Furthermore, the correlation coefficients between FA and myelin thickness (P = 0.027), FA and diameter of the myelinated fiber (P = 0.036), as well as RD and myelin thickness (P = 0.05) were statistically higher for the SS-EPI sequence compared with those for the RS-EPI sequence. ConclusionDiffusion tensor imaging analysis of the rat sciatic nerve showed that the image quality from the SS-EPI sequence was significantly higher compared with that from the RS-EPI sequence. Furthermore, the FA and RD derived from the SS-EPI sequence are promising and sensitive biomarkers to detect the histopathological changes in the rat sciatic nerve.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available