Optimal Location and Sizing of Distributed Generators in Power System Network with Power Quality Enhancement Using Fuzzy Logic Controlled D-STATCOM

Journal

SUSTAINABILITY
Volume 14, Issue 6, Pages -

Publisher

MDPI
DOI: 10.3390/su14063305

Keywords

distributed generator; D-STATCOM; fuzzy logic controller; genetic algorithm; power quality

Funding

  1. Taif University, Taif, Saudi Arabia [TURSP-2020/34]
  2. SHERIF GHONEIM

Ask authors/readers for more resources

This article presents a method for selecting multiple distributed generators (DGs) to improve the performance of radial distribution systems. The article proposes the use of a genetic algorithm and a heuristic probability distribution method to determine the optimal location and size of DGs. The article also evaluates the impact of introducing D-STATCOM and using a fuzzy logic controller on system performance. The results show that the genetic algorithm performs better than other methods in determining the optimal location and size of DGs.
This article presents the selection of location and sizing of multiple distributed generators (DGs) for boosting performance of the radial distribution system in the case of constant power load flow and constant impedance load flow. The consideration of placing and sizing of DGs is to meet the load demand. This article tries to overcome the limitations of existing techniques for determining the appropriate location and size of DGs. The selection of DG location is decided in terms of real power losses, accuracy, and sensitivity. The size of DG is measured in terms of real and reactive power. Both positioning and sizing of DG are analyzed with the genetic algorithm and the heuristic probability distribution method. The results are compared with other existing methods such as ant-lion optimization algorithm, coyote optimizer, modified sine-cosine algorithm, and particle swarm optimization. Further, the power quality improvement of the network is assessed by positioning D-STATCOM, and its location is decided on the basis of the nearby bus having poor voltage profile and high total harmonic distortion (THD). The switching and controlling of D-STATCOM are assessed with fuzzy logic controller (FLC) for improving the performance parameters such as voltage profile and THD at that particular bus. The proposed analytical approach for the system is tested on the IEEE 33 bus system. It is observed that the performance of the system with the genetic algorithm gives a better solution in comparison to heuristic PDF and other existing methods for determining the optimal location and size of DG. The introduction of D-STATCOM into the system with FLC shows better performance in terms of improved voltage profile and THD in comparison to existing techniques.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available