4.4 Review

Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part I-Development

Related references

Note: Only part of the references are listed.
Article Medical Laboratory Technology

Towards an SI-Traceable Reference Measurement System for Seven Serum Apolipoproteins Using Bottom-Up Quantitative Proteomics: Conceptual Approach Enabled by Cross-Disciplinary/Cross-Sector Collaboration

Christa M. Cobbaert et al.

Summary: Current dyslipidemia management in patients with ASCVD is based on traditional serum lipids, but research suggests that serum apolipoproteins may provide better insight into the root causes of dyslipidemia. Strategies for accurate testing of serum apolipoproteins should be developed in advance for future adoption in precision medicine. Recent discoveries in basic science and translational medicine have paved the way for the development of a multiplexed Reference Measurement System for apolipoproteins.

CLINICAL CHEMISTRY (2021)

Article Medical Laboratory Technology

Development of an LC-MS/MS Proposed Candidate Reference Method for the Standardization of Analytical Methods to Measure Lipoprotein(a)

Santica M. Marcovina et al.

Summary: The size polymorphism of apolipoprotein(a) affects immuno-chemical methods for lipoprotein(a) quantification. A LC-MS/MS method with a human recombinant apolipoprotein(a) reference material was developed, showing good accuracy, precision, and comparability, making it a potential candidate reference method for lipoprotein(a) standardization.

CLINICAL CHEMISTRY (2021)

Article Medical Laboratory Technology

More sensitivity is always better: Measuring sub-clinical levels of serum thyroglobulin on a μLC-MS/MS system

Christopher M. Shuford et al.

CLINICAL MASS SPECTROMETRY (2020)

Article Biochemistry & Molecular Biology

Performance of LC-MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome

Andrea Osswald et al.

JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY (2019)

Article Chemistry, Analytical

Salting out assisted liquid-liquid extraction for liquid chromatography tandem-mass spectrometry determination of amphetamine-like stimulants in meconium

Alzbeta Nemeskalova et al.

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS (2019)

Article Biochemical Research Methods

Ionization efficiency ladders as tools for choosing ionization mode and solvent in liquid chromatography/mass spectrometry

Riin Rebane et al.

RAPID COMMUNICATIONS IN MASS SPECTROMETRY (2019)

Editorial Material Biochemical Research Methods

What is novel about certified reference materials?

Stephen A. Wise

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2018)

Article Medical Laboratory Technology

Special Considerations for Liquid Chromatography-Tandem Mass Spectrometry Method Development

Brian A. Rappold

CLINICS IN LABORATORY MEDICINE (2018)

Article Medical Laboratory Technology

Evaluation of Stability of Thiopurine Metabolites Using a Validated LC-MS/MS Method

In-Young Yoo et al.

ANNALS OF LABORATORY MEDICINE (2018)

Article Biochemical Research Methods

Design of experiments for the optimization of electrospray ionization in the LC-MS/MS analysis of ciguatoxins

Guillermo Moreiras et al.

JOURNAL OF MASS SPECTROMETRY (2018)

Article Biochemical Research Methods

pH Effects on Electrospray Ionization Efficiency

Jaanus Liigand et al.

JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY (2017)

Review Chemistry, Analytical

Antibody based affinity capture LC-MS/MS in quantitative determination of proteins in biological matrices

Trine Gronhaug Halvorsen et al.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2017)

Article Chemistry, Analytical

Absolute Protein Quantification by Mass Spectrometry: Not as Simple as Advertised

Christopher M. Shuford et al.

ANALYTICAL CHEMISTRY (2017)

Review Medical Laboratory Technology

Applications of MALDI Mass Spectrometry in Clinical Chemistry

Mark W. Duncan et al.

CLINICAL CHEMISTRY (2016)

Editorial Material Medical Laboratory Technology

Mass Spectrometry Selectivity, Specifically

Brian A. Rappold

CLINICAL CHEMISTRY (2016)

Review Biochemical Research Methods

The impact of phospholipids and phospholipid removal on bioanalytical method performance

Jennifer Carmical et al.

BIOMEDICAL CHROMATOGRAPHY (2016)

Article Medical Laboratory Technology

Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update

Daniela Remane et al.

CLINICAL BIOCHEMISTRY (2016)

Article Biochemical Research Methods

Rapid screening for drugs of abuse in biological fluids by ultra high performance liquid chromatography/Orbitrap mass spectrometry

Eshwar Jagerdeo et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2016)

Article Environmental Sciences

Variation in concentration of perfluorooctanoic acid in methanol solutions during storage

Nobuyasu Hanari et al.

CHEMOSPHERE (2014)

Article Endocrinology & Metabolism

Clinical Utility of Simultaneous Quantitation of 25-Hydroxyvitamin D and 24,25-Dihydroxyvitamin D by LC-MS/MS Involving Derivatization With DMEQ-TAD

Martin Kaufmann et al.

JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM (2014)

Review Chemistry, Analytical

Ultra-high-pressure liquid chromatography (UHPLC) in method development

Michael W. Dong et al.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2014)

Article Medical Laboratory Technology

Salivary testosterone measurement by liquid chromatography tandem mass spectrometry in adult males and females

B. G. Keevil et al.

ANNALS OF CLINICAL BIOCHEMISTRY (2014)

Article Biochemical Research Methods

Sensitive routine liquid chromatography-tandem mass spectrometry method for serum estradiol and estrone without derivatization

Steven Pauwels et al.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2013)

Article Chemistry, Analytical

Improved quality-by-design compliant methodology for method development in reversed-phase liquid chromatography

Benjamin Debrus et al.

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS (2013)

Review Biochemical Research Methods

Salting-out assisted liquid-liquid extraction for bioanalysis

Yong Q. Tang et al.

BIOANALYSIS (2013)

Letter Medical Laboratory Technology

Potential problems with using deuterated internal standards for liquid chromatography-tandem mass spectrometry

A. S. Davison et al.

ANNALS OF CLINICAL BIOCHEMISTRY (2013)

Review Chemistry, Analytical

Past, Present, and Future of Solid Phase Extraction: A Review

Boguslaw Buszewski et al.

CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY (2012)

Review Food Science & Technology

The Arrhenius Equation Revisited

Micha Peleg et al.

CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION (2012)

Article Biochemical Research Methods

Identification of Known Unknowns Utilizing Accurate Mass Data and ChemSpider

James L. Little et al.

JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY (2012)

Review Biochemical Research Methods

Replacing immunoassays with tryptic digestion-peptide immunoaffinity enrichment and LC-MS/MS

Jessica Becker et al.

BIOANALYSIS (2012)

Review Microbiology

Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology

Antony Croxatto et al.

FEMS MICROBIOLOGY REVIEWS (2012)

Article Biochemical Research Methods

Direct quantification of cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry

David M. Schwope et al.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2011)

Article Medical Laboratory Technology

The stability of markers in dried-blood spots for recommended newborn screening disorders in the United States

B. W. Adam et al.

CLINICAL BIOCHEMISTRY (2011)

Article Medical Laboratory Technology

Quantification of 1α,25-Dihydroxy Vitamin D by Immunoextraction and Liquid Chromatography-Tandem Mass Spectrometry

Frederick G. Strathmann et al.

CLINICAL CHEMISTRY (2011)

Article Biochemical Research Methods

Free amino acid quantification by LC-MS/MS using derivatization generated isotope-labelled standards

David W. Johnson

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2011)

Article Biochemical Research Methods

A quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens

Mark S. Lowenthal et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2011)

Article Biochemical Research Methods

Quantitative urine amino acid analysis using liquid chromatography tandem mass spectrometry and aTRAQ® reagents

Patrice K. Held et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2011)

Review Spectroscopy

AN OVERVIEW OF MATRIX EFFECTS IN LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

Helga Trufelli et al.

MASS SPECTROMETRY REVIEWS (2011)

Article Biochemical Research Methods

Determination of lipoic acid in human plasma by HPLC-ECD using liquid-liquid and solid-phase extraction: Method development, validation and optimization of experimental parameters

Abad Khan et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2010)

Article Biochemical Research Methods

Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay

Johannes M. W. van den Ouweland et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2010)

Article Biochemical Research Methods

Investigation of endogenous blood plasma phospholipids, cholesterol and glycerides that contribute to matrix effects in bioanalysis by liquid chromatography/mass spectrometry

Omnia A. Ismaiel et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2010)

Article Medicine, General & Internal

Identification of Late-Onset Hypogonadism in Middle-Aged and Elderly Men

Frederick C. W. Wu et al.

NEW ENGLAND JOURNAL OF MEDICINE (2010)

Review Biochemical Research Methods

Bioanalytical solutions to acetonitrile shortages

Hong Gao et al.

BIOANALYSIS (2010)

Article Medical Laboratory Technology

A sensitive LC/MS/MS assay of 250H vitamin D3 and 250H vitamin D2 in dried blood spots

Darryl Eyles et al.

CLINICA CHIMICA ACTA (2009)

Article Chemistry, Analytical

Determination of Olanzapine in Whole Blood Using Simple Protein Precipitation and Liquid Chromatography-Tandem Mass Spectrometry

Marie Katrine Klose Nielsen et al.

JOURNAL OF ANALYTICAL TOXICOLOGY (2009)

Article Biochemical Research Methods

Rapid quantification of bile acids and their conjugates in serum by liquid chromatography-tandem mass spectrometry

Max Scherer et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2009)

Article Biochemical Research Methods

Development and validation of an LC-MS/MS method for the quantification of ephedrines in urine

K. Deventer et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2009)

Article Pathology

High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol

Mark M. Kushnir et al.

AMERICAN JOURNAL OF CLINICAL PATHOLOGY (2008)

Article Chemistry, Analytical

Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry

Achille Cappiello et al.

ANALYTICAL CHEMISTRY (2008)

Article Biochemical Research Methods

Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry

Sys Stybe Johansen et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2007)

Article Biochemical Research Methods

Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses

Erin Chambers et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2007)

Article Endocrinology & Metabolism

Association of testosterone and estradiol deficiency with osteoporosis and rapid bone loss in older men

Howard A. Fink et al.

JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM (2006)

Article Biochemical Research Methods

Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma

JL Little et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2006)

Article Medical Laboratory Technology

Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone

MM Kushnir et al.

CLINICAL CHEMISTRY (2006)

Article Biochemical Research Methods

Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry

A Covaci et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2005)

Article Chemistry, Analytical

Validation of quantitative NMR

F Malz et al.

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS (2005)

Article Biochemical Research Methods

Statistical design of experiments as a tool in mass spectrometry

LS Riter et al.

JOURNAL OF MASS SPECTROMETRY (2005)

Review Medical Laboratory Technology

Assessing analytical specificity in quantitative analysis using tandem mass spectrometry

MM Kushnir et al.

CLINICAL BIOCHEMISTRY (2005)

Letter Medical Laboratory Technology

Precisely wrong? Urinary fractionated metanephrines and peer-based laboratory proficiency testing

RJ Singh et al.

CLINICAL CHEMISTRY (2005)

Review Biochemical Research Methods

Derivatization of neutral steroids to enhance their detection characteristics in liquid chromatography-mass spectrometry

T Higashi et al.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2004)

Article Biochemical Research Methods

Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry

C Polson et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2003)