4.6 Article

A building energy models calibration methodology based on inverse modelling approach

Journal

BUILDING SIMULATION
Volume 15, Issue 11, Pages 1883-1898

Publisher

TSINGHUA UNIV PRESS
DOI: 10.1007/s12273-022-0900-5

Keywords

internal thermal mass; energy simulation; EnergyPlus; inverse model; Annex 58; infiltration

Funding

  1. CRUE-CSIC agreement
  2. Springer Nature

Ask authors/readers for more resources

This paper presents a new calibration methodology for energy models, which reduces execution time and uncertainties by implementing an inverse modeling approach and empirical validation. The findings show that the data generated with this methodology significantly improve resemblance to real monitoring data.
Nowadays, building energy models (BEMs) are widely used, particularly in the assessment of energy consumption in buildings to address the potential savings that can be generated. The realisation of a dynamic energy model based on high-fidelity physics (white-box models) requires a tuning process to fit the model to reality, due to many uncertainties involved. Currently some research trends try to reduce this performance gap by modulating different types of experimental parameters such as: capacitances or infiltration. The EnergyPlus simulation software, in its latest versions, has implemented an object: HybridModel:Zone that calculates the infiltration and internal mass of buildings using an inverse modelling approach that employs only the measured indoor temperature data to invert the heat balance equation for the zone under study. The main objective of this paper is to reduce the execution time and uncertainties in the development of quality energy models by generating a new calibration methodology that implements this approach. This uses, as a starting point, a research created by the authors of this study, which was empirically and comparatively validated against the energy models developed by the participants in Annex 58. It is also worth highlighting the empirical validation of the HybridModel:Zone object, since it was activated in all scenarios where its execution is possible: periods of seven days or more of free oscillation and periods in which the building is under load. The findings are promising. The data generated with the new methodology, if compared with those produced by the baseline model, improve their resemblance to the real ones by 22.9%. While those of its predecessor did it by 15.6%. For this study, the two dwellings foreseen in Annex 58 of the IEA ECB project have been modelled and their real monitoring data have been used.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available