4.6 Article

Retinal magnification factors at the fixation locus derived from schematic eyes with four individualized surfaces

Journal

BIOMEDICAL OPTICS EXPRESS
Volume 13, Issue 7, Pages 3786-3808

Publisher

Optica Publishing Group
DOI: 10.1364/BOE.460553

Keywords

-

Funding

  1. National Eye Institute [P30EY026877, R01EY027301, R01EY030361, R01EY031360, R01EY032147, R01EY032669]
  2. Research to Prevent Blindness
  3. Stanford Center for Optic Disc Drusen at the Byers Eye Institute

Ask authors/readers for more resources

This study proposes methods for calculating retinal magnification factors (RMFs) that take into account individual ocular biometry. The results show minimal differences between the two methods compared to widely used approaches. The study also reveals a relationship between RMF changes and refractive error, as well as the axial separation between the entrance pupil and the exit pupil of the ophthalmoscope. Furthermore, the study finds weak correlation between surface radii and refractive error, while vitreous thickness shows a strong correlation. Lastly, the study suggests reporting individual ocular biometry data and detailed RMF calculation method descriptions in scientific publications to facilitate data comparison in retinal imaging biomarkers across studies.
Retinal magnification factors (RMFs) allow the conversion of angles to lengths in retinal images. In this work, we propose paraxial and non-paraxial RMF calculation methods that incorporate the individual topography and separation of the anterior and posterior surfaces of the cornea and crystalline lens, assuming homogeneous ocular media. Across 34 eyes, the two RMF methods differ by 0.1% on average, due to surface tilt, decenter, and lack of rotational symmetry in the non-paraxial modeling, which results in up to 2.2% RMF variation with retinal meridian. Differences with widely used individualized RMF calculation methods are smallest for eyes with similar to 24 mm axial length, and as large as 7.5% in a 29.7 mm long eye (15D myope). To better model the capture of retinal images, we propose the tracing of chief rays, instead of the scaling of posterior nodal or principal distances often used in RMF definitions. We also report that RMF scale change is approximately proportional to both refractive error and axial separation between the ophthalmoscope's exit pupil and the eye's entrance pupil, resulting in RMF changes as large as 13% for a 1cm displacement in a 15D myopic eye. Our biometry data shows weak correlation and statistical significance between surface radii and refractive error, as well as axial length, whether considering all eyes in the study, or just the high myopes, defined as those with refractive error sphere equivalent <= -4D. In contrast, vitreous thicknesses show a strong correlation (r <= -0.92) and significance (p <= 10(-13)) with refractive error when considering all eyes or just high myopes (r <= -0.95; p <= 10(-5)). We also found that potential RMF change with depth of cycloplegia and/or residual accommodation is smaller than 0.2%. Finally, we propose the reporting of individual ocular biometry data and a detailed RMF calculation method description in scientific publications to facilitate the comparison of retinal imaging biomarker data across studies. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available