4.0 Article

Effect of sodium hypochlorite, isopropyl alcohol and chlorhexidine on the epoxy sealant penetration into the dentinal tubules

Journal

ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE
Volume 31, Issue 2, Pages 121-127

Publisher

WROCLAW MEDICAL UNIV
DOI: 10.17219/acem/142991

Keywords

obturation; chlorhexidine; AH PlusTM; confocal laser scanning microscopy; dentinal tubules penetration

Funding

  1. European Regional Development Fund in the framework of the Polish Innovation Economy Operational Program [POIG.02.01.00-12-023/08]

Ask authors/readers for more resources

This study investigated the effect of three different irrigants on the penetration of an epoxy sealer into dentinal tubules. The results showed that final irrigation with chlorhexidine resulted in the deepest penetration of the sealer, while isopropyl alcohol had the most negative impact on sealer penetration.
Background. The sealer penetration into the dentinal tubules might be beneficial, especially in necrotic endodontic cases, as it provides the obstruction of the contaminated tubules. Objectives. To determine the effect of 3 final irrigants (sodium hypochlorite (NaOCl), alcohol and chlorhexidine (CHX)) on the penetration of an epoxy sealer into the dentinal tubules. Materials and methods. The study was carried out on 60 single-canal human teeth with straight roots. The root canals were prepared to the ISO 40/04 size, using the Reciproc (R) instruments. The teeth were divided into 4 groups (n = 15). The canals in each group were irrigated according to the following scheme: group 1 (control) - 5.25% NaOCl; group 2 - smear layer removal (40% citric acid (CA) and 5.25% NaOCl) and 5.25% NaOCl; group 3 - smear layer removal (as in group 2), and 40% CA, water and 98% isopropyl alcohol; and group 4 - smear layer removal (as in group 2), and 40% CA, water and 2% CHX. The root canals were filled using the vertical condensation technique with gutta-percha and the porphyrin-labeled AH PlusTM sealer. After 3 days, 1-milimeter-thick cross-section slices were cut from the roots at a distance of 2 mm, 5 mm and 8 mm from the apex. The sections were imaged under a confocal microscope and the sealant penetration depth into the dentinal tubules was measured. Results. The longest resin tags in all parts of the roots were found in group 4 (CHX), and the shortest in group 1 (control). The mean depth of the sealer penetration (in micrometers) was as follows: 21, 22 Conclusions. The final irrigation with CHX resulted in the deepest penetration of the epoxy sealer into the tubules. Isopropyl alcohol had the most negative impact on the sealer penetration into the tubules.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available