4.7 Article

Enhanced photoacoustic imaging in tissue-mimicking phantoms using polydopamine-shelled perfluorocarbon emulsion droplets

Journal

ULTRASONICS SONOCHEMISTRY
Volume 86, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.ultsonch.2022.106041

Keywords

-

Funding

  1. Monash University
  2. Graduate Research Completion Award (GRCA)
  3. Postgraduate Publication Award (PPA)

Ask authors/readers for more resources

This study optimized the process parameters for ultrasound-assisted fabrication of polydopamine-shelled perfluorocarbon emulsion droplets. The results showed that emulsion droplets with bimodal size distributions exhibited significant photoacoustic signal enhancement. The performance of these droplets in mimicked tissue media was evaluated, demonstrating that the bimodal droplets can enhance the photoacoustic signal up to five folds. Furthermore, using enhanced photoacoustic images, the maximal tissue imaging depths were explored for the droplets, indicating potential applications in theranostics and other imaging modalities.
The current work features process parameters for the ultrasound (25 kHz)-assisted fabrication of polydopamine-shelled perfluorocarbon (PDA/PFC) emulsion droplets with bimodal (modes at 100-600 nm and 1-6 mu m) and unimodal (200-600 nm) size distributions. Initial screening of these materials revealed that only PDA/PFC emulsion droplets with bimodal distributions showed photoacoustic signal enhancement due to large size of their optically absorbing PDA shells. Performance of this particular type of emulsion droplets as photoacoustic agents were evaluated in Intralipid (R)-India ink media, mimicking the optical scattering and absorbance of various tissue types. From these measurements, it was observed that PDA/PFC droplets with bimodal size distributions can enhance the photoacoustic signal of blood-mimicking phantom by up to five folds in various tissue-mimicking phantoms with absorption coefficients from 0.1 to 1.0 cm(-1). Furthermore, using the information from enhanced photoacoustic images at 750 nm, the ultimate imaging depth was explored for polydopamine-shelled, perfluorohexane (PDA/PFH) emulsion droplets by photon trajectory simulations in 3D using a Monte Carlo approach. Based on these simulations, maximal tissue imaging depths for PDA/PFH emulsion droplets range from 10 to 40 mm, depending on the tissue type. These results demonstrate for the first time that ultrasonically fabricated PDA/PFC emulsion droplets have great potential as photoacoustic imaging agents that can be complemented with other reported characteristics of PDA/PFC emulsion droplets for extended applications in theranostics and other imaging modalities.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available