4.7 Article

Sensitive detection of trace level Cd (II) triggered by chelation enhanced fluorescence (CHEF) turn on: Nitrogen-doped graphene quantum dots (N-GQDs) as fluorometric paper-based sensor

Journal

TALANTA
Volume 242, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2022.123305

Keywords

Cadmium ion (Cd (II)); Nitrogen-doped graphene quantum dots (N-GQDs); Fluorescent sensor; Paper-based sensor; Chelation enhanced fluorescence (CHEF)

Funding

  1. Department of Chemistry, Faculty of Science, Ubon Ratchathani University
  2. National Research Council of Thailand [IRN/502/2563]
  3. Department of Chemistry, Faculty of Science, Ubon RatchathaniUniversity
  4. Science Achievement Scholarship of Thailand (SAST)

Ask authors/readers for more resources

This study developed a fluorescent sensor based on nitrogen-doped graphene quantum dots for the determination of Cd (II) concentration in water and herbal medicine samples. The sensor demonstrated high sensitivity, high selectivity, and short incubation time.
Cadmium ion (Cd (II)) is a highly toxic heavy metal usually found in natural water. Exposure to Cd (II) can produce serious effects in human organs such as Itai-Itai disease. Therefore, the maximum allowance levels of Cd (II) in drinking water and herbal medicines imposed by the World Health Organization (WHO) are 3 mu g L-1 and 300 mu g kg(-1), respectively. In this work, nitrogen-doped graphene quantum dots (N-GQDs) as a fluorescent sensor for Cd (II) determination was developed in both solution-based and paper-based systems. N-GQDs were synthesized from citric acid (CA) and ethylenediamine (EDA) via the hydrothermal method. The synthesized NGQDs emitted intense blue fluorescence with a quantum yield (QY) of up to 80%. The functional groups on the surface of N-GQDs measured by FTIR were carboxyl (COO-), hydroxyl (OH-), and amine (NH2) groups, suggesting that they could be bound to Cd (II) for complexation. The fluorescence intensity of N-GQDs was gradually enhanced with the increase of Cd (II) concentration. This phenomenon was proved to result from the fluorescence enhancement (turn-on) based on the chelation enhanced fluorescence (CHEF) mechanism. Under the optimum conditions in the solution-based and paper-based systems, the limits of detection (LODs) were found to be 1.09 and 0.59 mu g L-1, respectively. Furthermore, the developed sensors showed relatively high selectivity toward Cd (II) over ten other metal cations and six other anions of different charges. The performance of the sensor in real water and herbal medicine samples exhibited no significant difference as compared to the results of the validation method (ICP-OES). Therefore, the developed sensors can be used as fluorescent sensors for Cd (II) determination with high sensitivity, high selectivity, short incubation time (5 min). As such, the paper-based strategy has excellent promising potential for practical analysis of Cd (II) in water and herbal medicine samples with a trace level of Cd (II) concentrations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available