4.8 Article

Microfluidic Impedance-Deformability Cytometry for Label-Free Single Neutrophil Mechanophenotyping

Related references

Note: Only part of the references are listed.
Article Chemistry, Multidisciplinary

Label-Free Biophysical Markers from Whole Blood Microfluidic Immune Profiling Reveal Severe Immune Response Signatures

Kerwin Kwek Zeming et al.

Summary: Current methods for early diagnosis of infections are time-consuming and of low sensitivity, while the new approach of profiling host inflammatory response may provide a rapid way to identify severity of inflammation, making it potentially impactful for triage and resource allocation in emergency departments for acute infections.

SMALL (2021)

Article Hematology

A neutrophil activation signature predicts critical illness and mortality in COVID-19

Matthew L. Meizlish et al.

Summary: Pathologic immune hyperactivation, particularly neutrophil activation, plays a central role in severe COVID-19, with early markers predicting clinical decompensation and higher mortality rates. These findings highlight the importance of understanding immune responses in critically ill COVID-19 patients.

BLOOD ADVANCES (2021)

Article Biophysics

Physical phenotype of blood cells is altered in COVID-19

Marketa Kubankova et al.

Summary: Various physical parameters of blood cells, including lymphocyte stiffness, monocyte size, neutrophil size and deformability, and heterogeneity of erythrocyte deformation and size, were found to change significantly in COVID-19 patients. While some of these changes recovered after hospitalization, others persisted for months after discharge, demonstrating the long-term impact of COVID-19 on the body.

BIOPHYSICAL JOURNAL (2021)

Article Chemistry, Analytical

Label-free quantitative lymphocyte activation profiling using microfluidic impedance cytometry

Chayakorn Petchakup et al.

Summary: This study presents a new method for studying lymphocytes based on impedance, which can quickly screen the responses of specific antigen-specific T lymphocytes and be used for the characterization of host immunity and the diagnosis of infectious diseases.

SENSORS AND ACTUATORS B-CHEMICAL (2021)

Article Multidisciplinary Sciences

Measuring expression heterogeneity of single-cell cytoskeletal protein complexes

Julea Vlassakis et al.

Summary: This research introduces a novel method to simultaneously detect protein complexes in stressed cell populations, revealing potential cellular responses to specific treatments. The study also highlights the impact of non-chemical stress on cellular heterogeneity of F-actin. The assay developed in this work overcomes selectivity limitations to biochemically quantify single-cell protein complexes perturbed with diverse stimuli.

NATURE COMMUNICATIONS (2021)

Review Biochemical Research Methods

Single-cell microfluidic impedance cytometry: from raw signals to cell phenotypes using data analytics

Carlos Honrado et al.

Summary: Microfluidic impedance cytometry is a label-free and high-throughput method for stratifying cellular systems based on electrophysiology, with applications ranging from life science research to precision medicine. Novel chip designs and data analytic strategies are laying the foundation for multiparametric cell characterization and subpopulation distinction, essential for understanding biological function and disease progression. Emerging developments in the technique, such as device design, data analytics, and phenotyping applications, offer exciting prospects for future challenges and directions in label-free quantification and isolation of subpopulations in heterogeneous biosystems.

LAB ON A CHIP (2021)

Article Biochemical Research Methods

A comparison of microfluidic methods for high-throughput cell deformability measurements

Marta Urbanska et al.

NATURE METHODS (2020)

Article Biophysics

Cells Under Stress: An Inertial-Shear Microfluidic Determination of Cell Behavior

Fern J. Armistead et al.

BIOPHYSICAL JOURNAL (2019)

Article Multidisciplinary Sciences

Neutrophil activation and NETosis are the major drivers of thrombosis in heparin-induced thrombocytopenia

Jose Perdomo et al.

NATURE COMMUNICATIONS (2019)

Article Biochemical Research Methods

Impedance-based viscoelastic flow cytometry

Murat Serhatlioglu et al.

ELECTROPHORESIS (2019)

Letter Critical Care Medicine

Rapid Biophysical Analysis of Host Immune Cell Variations Associated with Sepsis

Katherine Crawford et al.

AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE (2018)

Article Chemistry, Analytical

A novel wiring scheme for standard chips enabling high-accuracy impedance cytometry

Federica Caselli et al.

SENSORS AND ACTUATORS B-CHEMICAL (2018)

Review Physiology

Neutrophil: A Cell with Many Roles in Inflammation or Several Cell Types?

Carlos Rosales

FRONTIERS IN PHYSIOLOGY (2018)

Article Biophysics

Label-free leukocyte sorting and impedance-based profiling for diabetes testing

Chayakorn Petchakup et al.

BIOSENSORS & BIOELECTRONICS (2018)

Article Multidisciplinary Sciences

Chromatin swelling drives neutrophil extracellular trap release

Elsa Neubert et al.

NATURE COMMUNICATIONS (2018)

Article Chemistry, Analytical

Characterizing Deformability and Electrical Impedance of Cancer Cells in a Microfluidic Device

Ying Zhou et al.

ANALYTICAL CHEMISTRY (2018)

Review Cell Biology

Plasma membrane changes during programmed cell deaths

Yingying Zhang et al.

CELL RESEARCH (2018)

Article Biochemical Research Methods

Coplanar electrode microfluidic chip enabling accurate sheathless impedance cytometry

Adele De Ninno et al.

LAB ON A CHIP (2017)

Article Physics, Multidisciplinary

Actin and microtubule networks contribute differently to cell response for small and large strains

H. Kubitschke et al.

NEW JOURNAL OF PHYSICS (2017)

Review Chemistry, Analytical

Advances in Single Cell Impedance Cytometry for Biomedical Applications

Chayakorn Petchakup et al.

MICROMACHINES (2017)

Article Multidisciplinary Sciences

Mechanical deformation induces depolarization of neutrophils

Andrew E. Ekpenyong et al.

SCIENCE ADVANCES (2017)

Article Biochemical Research Methods

Microfluidic differential immunocapture biochip for specific leukocyte counting

Umer Hassan et al.

NATURE PROTOCOLS (2016)

Article Multidisciplinary Sciences

Rapid and label-free microfluidic neutrophil purification and phenotyping in diabetes mellitus

Han Wei Hou et al.

SCIENTIFIC REPORTS (2016)

Article Multidisciplinary Sciences

Multiparameter mechanical and morphometric screening of cells

Mahdokht Masaeli et al.

Scientific Reports (2016)

Review Cell Biology

Distinct Functions of Neutrophil in Cancer and Its Regulation

Zvi Granot et al.

MEDIATORS OF INFLAMMATION (2015)

Article Biochemistry & Molecular Biology

Diabetes primes neutrophils to undergo NETosis, which impairs wound healing

Siu Ling Wong et al.

NATURE MEDICINE (2015)

Article Biochemical Research Methods

Real-time deformability cytometry: on-the-fly cell mechanical phenotyping

Oliver Otto et al.

NATURE METHODS (2015)

Article Biochemical Research Methods

An impedance-based flow microcytometer for single cell morphology discrimination

M. Shaker et al.

LAB ON A CHIP (2014)

Article Biochemical Research Methods

Pinched-flow hydrodynamic stretching of single-cells

Jaideep S. Dudani et al.

LAB ON A CHIP (2013)

Article Biochemical Research Methods

A microfluidic impedance flow cytometer for identification of differentiation state of stem cells

Hongjun Song et al.

LAB ON A CHIP (2013)

Article Chemistry, Analytical

Microfluidics-Based Assessment of Cell Deformability

Andrea Adamo et al.

ANALYTICAL CHEMISTRY (2012)

Article Multidisciplinary Sciences

Viscoelastic Properties of Differentiating Blood Cells Are Fate- and Function-Dependent

Andrew E. Ekpenyong et al.

PLOS ONE (2012)

Article Multidisciplinary Sciences

Hydrodynamic stretching of single cells for large population mechanical phenotyping

Daniel R. Gossett et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2012)

Article Biochemical Research Methods

Positional dependence of particles in microfludic impedance cytometry

Daniel Spencer et al.

LAB ON A CHIP (2011)

Review Nanoscience & Nanotechnology

Single-cell microfluidic impedance cytometry: a review

Tao Sun et al.

MICROFLUIDICS AND NANOFLUIDICS (2010)

Article Oncology

Failure of neutrophil chemotactic function in breast cancer patients treated with chemotherapy

MAO Mendonça et al.

CANCER CHEMOTHERAPY AND PHARMACOLOGY (2006)

Article Biochemistry & Molecular Biology

Differentiated HL-60 cells are a valid model system for the analysis of human neutrophil migration and chemotaxis

AB Hauert et al.

INTERNATIONAL JOURNAL OF BIOCHEMISTRY & CELL BIOLOGY (2002)

Article Critical Care Medicine

Neutrophil deformability in patients with sepsis, septic shock, and adult respiratory distress syndrome

AT Skoutelis et al.

CRITICAL CARE MEDICINE (2000)