4.6 Article

Electrocardiogram Biometrics Using Transformer's Self-Attention Mechanism for Sequence Pair Feature Extractor and Flexible Enrollment Scope Identification

Journal

SENSORS
Volume 22, Issue 9, Pages -

Publisher

MDPI
DOI: 10.3390/s22093446

Keywords

transformer; BERT; ECG biometrics; self-attention mechanism; deep learning; multi-class classification; convolutional neural network; feature extraction; blind segmentation; artificial neural network

Funding

  1. Ministry of Higher Education Malaysia [FRGS/1/2020/ICT03/USM/02/1]

Ask authors/readers for more resources

In this research, a sequence pair feature extractor inspired by Transformer is proposed for ECG identification tasks. The model achieves high accuracy in identifying ECGs collected in a short time separation and shows significant improvement over existing methods for a long time separation.
The existing electrocardiogram (ECG) biometrics do not perform well when ECG changes after the enrollment phase because the feature extraction is not able to relate ECG collected during enrollment and ECG collected during classification. In this research, we propose the sequence pair feature extractor, inspired by Bidirectional Encoder Representations from Transformers (BERT)'s sentence pair task, to obtain a dynamic representation of a pair of ECGs. We also propose using the self-attention mechanism of the transformer to draw an inter-identity relationship when performing ECG identification tasks. The model was trained once with datasets built from 10 ECG databases, and then, it was applied to six other ECG databases without retraining. We emphasize the significance of the time separation between enrollment and classification when presenting the results. The model scored 96.20%, 100.0%, 99.91%, 96.09%, 96.35%, and 98.10% identification accuracy on MIT-BIH Atrial Fibrillation Database (AFDB), Combined measurement of ECG, Breathing and Seismocardiograms (CEBSDB), MIT-BIH Normal Sinus Rhythm Database (NSRDB), MIT-BIH ST Change Database (STDB), ECG-ID Database (ECGIDDB), and PTB Diagnostic ECG Database (PTBDB), respectively, over a short time separation. The model scored 92.70% and 64.16% identification accuracy on ECGIDDB and PTBDB, respectively, over a long time separation, which is a significant improvement compared to state-of-the-art methods.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available