4.6 Article

Adversarial Resolution Enhancement for Electrical Capacitance Tomography Image Reconstruction

Journal

SENSORS
Volume 22, Issue 9, Pages -

Publisher

MDPI
DOI: 10.3390/s22093142

Keywords

ECT; image reconstruction; deep learning; CGAN; ARE-ECT

Funding

  1. Deanship of Scientific Research at Umm Al-Qura University [22UQU4310447DSR01]

Ask authors/readers for more resources

In this paper, a novel adversarial resolution enhancement model (ARE-ECT) is proposed for reconstructing high-resolution electrical capacitance tomography (CT) images. The model shows superior performance in training with low-quality initial images and generating high-resolution images. The evaluation results demonstrate the superiority of the ARE-ECT model over traditional methods and other deep learning models in generating more accurate CT images.
High-quality image reconstruction is essential for many electrical capacitance tomography (CT) applications. Raw capacitance measurements are used in the literature to generate low-resolution images. However, such low-resolution images are not sufficient for proper functionality of most systems. In this paper, we propose a novel adversarial resolution enhancement (ARE-ECT) model to reconstruct high-resolution images of inner distributions based on low-quality initial images, which are generated from the capacitance measurements. The proposed model uses a UNet as the generator of a conditional generative adversarial network (CGAN). The generator's input is set to the low-resolution image rather than the typical random input signal. Additionally, the CGAN is conditioned by the input low-resolution image itself. For evaluation purposes, a massive ECT dataset of 320 K synthetic image-measurement pairs was created. This dataset is used for training, validating, and testing the proposed model. New flow patterns, which are not exposed to the model during the training phase, are used to evaluate the feasibility and generalization ability of the ARE-ECT model. The superiority of ARE-ECT, in the efficient generation of more accurate ECT images than traditional and other deep learning-based image reconstruction algorithms, is proved by the evaluation results. The ARE-ECT model achieved an average image correlation coefficient of more than 98.8% and an average relative image error about 0.1%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available