4.6 Article

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

Journal

SENSORS
Volume 22, Issue 8, Pages -

Publisher

MDPI
DOI: 10.3390/s22083059

Keywords

calibration; sensor localization; co-registration; optically pumped magnetometer; magnetoencephalography; on-scalp MEG; fluxgate magnetometer; electromagnetic coil

Funding

  1. National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health [U01EB028656]
  2. European Research Council [678578]
  3. European Research Council (ERC) [678578] Funding Source: European Research Council (ERC)

Ask authors/readers for more resources

This paper proposes a method for calibrating and localizing magnetic field sensors using electromagnetic coils. The method is applied to optically pumped magnetometers in magnetoencephalography. By measuring the coil fields, modeling them, and minimizing the errors, the sensor parameters can be obtained. Experimental results confirm the feasibility of this method.
In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2 degrees, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available