4.6 Review

Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors

Related references

Note: Only part of the references are listed.
Review Engineering, Biomedical

A Review of Techniques for Surface Electromyography Signal Quality Analysis

Emma Farago et al.

Summary: Electromyography (EMG) signals are important for various applications, but signal contaminants can degrade the signal quality. Different strategies need to be used to detect and quantify these contaminants, depending on the circumstances of data collection.

IEEE REVIEWS IN BIOMEDICAL ENGINEERING (2023)

Review Physiology

The Accurate Assessment of Muscle Excitation Requires the Detection of Multiple Surface Electromyograms

Taian Martins Vieira et al.

Summary: When sampling EMGs with one pair of electrodes, it is not sufficient to assume that the detected signal reflects the net muscle excitation. Multiple EMG detections and consideration of electrode-fiber alignment are necessary for accurate assessment of muscle excitation. It is advisable to exercise caution when drawing inferences from individually collected EMGs.

EXERCISE AND SPORT SCIENCES REVIEWS (2021)

Review Chemistry, Analytical

Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review

Andrea Merlo et al.

Summary: The proper placement of electrodes on the brachioradialis muscle is crucial for accurate sEMG measurements, but studies have found a lack of awareness and training in handling crosstalk issues. It is essential to follow guideline recommendations, use miniaturized electrodes, and place them on specific areas to ensure reliability of the measurements.

SENSORS (2021)

Article Clinical Neurology

sEMG: A Window Into Muscle Work, but Not Easy to Teach and Delicate to Practice-A Perspective on the Difficult Path to a Clinical Tool

Bernard J. Martin et al.

Summary: The application of sEMG method is not a simple operation and requires creativity, training, and practice. It is necessary to have a foundation of knowledge and skills in multiple disciplines to interpret muscle functioning correctly.

FRONTIERS IN NEUROLOGY (2021)

Article Chemistry, Analytical

Monitoring Involuntary Muscle Activity in Acute Patients with Upper Motor Neuron Lesion by Wearable Sensors: A Feasibility Study

Andrea Merlo et al.

Summary: This study demonstrated the feasibility of using wearable probes for single differential sEMG to identify and quantify IMA in paralyzed muscles of bedridden acute neurological patients. The results also suggest the need for long-lasting acquisitions for proper characterization of IMA. The ability to easily assess IMA in acute inpatients can significantly impact the management of their postures, physiotherapy, and treatments.

SENSORS (2021)

Article Engineering, Industrial

Bipolar versus high-density surface electromyography for evaluating risk in fatiguing frequency-dependent lifting activities

Tiwana Varrecchia et al.

Summary: The study showed that high-density surface electromyography (HDsEMG) data had higher discriminative power in detecting lifting fatigue compared to traditional bipolar sEMG, able to distinguish risk levels earlier in the lifting task.

APPLIED ERGONOMICS (2021)

Article Neurosciences

Consensus for experimental design in electromyography (CEDE) project: Terminology matrix

Lara McManus et al.

Summary: This paper presents a matrix developed within the Consensus for Experimental Design in Electromyography (CEDE) project, providing definitions for terms used in the EMG literature. The definitions for physiological and technical terms that are common in EMG research are included in two tables, with key information on each definition provided in a comment section.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2021)

Review Neurosciences

Clinical efficacy of instrumented gait analysis: Systematic review 2020 update

Tishya A. L. Wren et al.

GAIT & POSTURE (2020)

Editorial Material Neurosciences

Gait and Posture Virtual Special Issue Clinical Impact of Instrumented Motion Analysis

Tishya A. L. Wren et al.

GAIT & POSTURE (2020)

Article Neurosciences

Consensus for experimental design in electromyography (CEDE) project: Amplitude normalization matrix

Manuela Besomi et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2020)

Article Neurosciences

Tutorial. Surface EMG detection, conditioning and pre-processing: Best practices

R. Merletti et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2020)

Article Clinical Neurology

Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use

Isabella Campanini et al.

FRONTIERS IN NEUROLOGY (2020)

Article Clinical Neurology

A Survey on the Use and Barriers of Surface Electromyography in Neurorehabilitation

Andrea Manca et al.

FRONTIERS IN NEUROLOGY (2020)

Review Medicine, General & Internal

Botulinurn toxin type A therapy for cervical dystonia

Filipe B. Rodrigues et al.

COCHRANE DATABASE OF SYSTEMATIC REVIEWS (2020)

Review Clinical Neurology

Surface Electromyography: What Limits Its Use in Exercise and Sport Physiology?

Francesco Felici et al.

FRONTIERS IN NEUROLOGY (2020)

Article Engineering, Biomedical

Two-dimensional surface EMG: The effects of electrode size, interelectrode distance and image truncation

B. Afsharipour et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2019)

Article Neurosciences

Consensus for experimental design in electromyography (CEDE) project: Electrode selection matrix

Manuela Besomi et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2019)

Article Medicine, General & Internal

HDsEMG Activity of the Lumbar Erector Spinae in Violin Players Comparison of Two Chairs

Alessandro Russo et al.

MEDICAL PROBLEMS OF PERFORMING ARTISTS (2019)

Article Neurosciences

Tutorial. Surface EMG detection in space and time: Best practices

R. Merletti et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2019)

Article Engineering, Biomedical

Spatial Analysis of Multichannel Surface EMG in Hemiplegic Stroke

Ghulam Rasool et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2017)

Editorial Material Orthopedics

Overcoming Ignorance and Ineptitude in 21st Century Rehabilitation

Alan M. Jette

PHYSICAL THERAPY (2017)

Article Obstetrics & Gynecology

Functional mapping of the pelvic floor and sphincter muscles from high-density surface EMG recordings

Yun Peng et al.

INTERNATIONAL UROGYNECOLOGY JOURNAL (2016)

Editorial Material Orthopedics

Moving Research From the Bedside Into Practice

Alan M. Jette

PHYSICAL THERAPY (2016)

Article Clinical Neurology

Motor endplate-targeted botulinum toxin injections of the gracilis muscle in children with cerebral palsy

Anja Van Campenhout et al.

DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY (2015)

Article Engineering, Biomedical

High-density Surface EMG: Techniques and Applications at a Motor Unit Level

Stegeman Dick F. et al.

Biocybernetics and Biomedical Engineering (2013)

Article Neurosciences

A method to differentiate the causes of stiff-knee gait in stroke patients

I. Campanini et al.

GAIT & POSTURE (2013)

Article Neurosciences

Feasibility study of detecting surface electromyograms in severely obese patients

Marco A. Minetto et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2013)

Review Microbiology

High density electroencephalography in sleep research: potential, problems, future perspective

Caroline Lustenberger et al.

FRONTIERS IN MICROBIOLOGY (2012)

Review Neurosciences

Efficacy of clinical gait analysis: A systematic review

Tishya A. L. Wren et al.

GAIT & POSTURE (2011)

Article Neurosciences

Mechanisms of cramp contractions: peripheral or central generation?

Marco Alessandro Minetto et al.

JOURNAL OF PHYSIOLOGY-LONDON (2011)

Article Urology & Nephrology

Repeatability of Innervation Zone Identification in the External Anal Sphincter Muscle

Paul Enck et al.

NEUROUROLOGY AND URODYNAMICS (2010)

Article Neurosciences

Motor unit discharge pattern and conduction velocity in patients with upper motor neuron syndrome

Isabella Campanini et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2009)

Article Physiology

Surface EMG signal alterations in Carpal Tunnel syndrome: a pilot study

A. Rainoldi et al.

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY (2008)

Article Neurosciences

Effect of electrode location on EMG signal envelope in leg muscles during gait

I. Campanini et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2007)

Article Neurosciences

Neuromuscular responses to exercise investigated through surface EMG

Francesco Felici

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2006)

Article Neurosciences

Clinical applications of high-density surface EMG: A systematic review

Gea Drost et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2006)

Article Clinical Neurology

Clinical applications of surface electromyography in neuromuscular disorders

JY Hogrel

NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY (2005)

Article Engineering, Biomedical

A surface EMG generation model with multilayer cylindrical description of the volume conductor

D Farina et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2004)

Article Computer Science, Interdisciplinary Applications

Correlation-based decomposition of surface electromyograms at low contraction forces

A Holobar et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2004)

Article Clinical Neurology

Multichannel surface EMG: Basic aspects and clinical utility

MJ Zwarts et al.

MUSCLE & NERVE (2003)

Article Neurosciences

Development of recommendations for SEMG sensors and sensor placement procedures

HJ Hermens et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2000)

Review Physiology

Non-invasive approach of motor unit recording during muscle contractions in humans

C Disselhorst-Klug et al.

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY (2000)