Sampling Trade-Offs in Duty-Cycled Systems for Air Quality Low-Cost Sensors

Journal

SENSORS
Volume 22, Issue 10, Pages -

Publisher

MDPI
DOI: 10.3390/s22103964

Keywords

air quality; low-cost sensors; sampling; sensor calibration; duty cycle

Funding

  1. Secretaria d'Universitats i Recerca de la Generalitat de Catalunya i del Fons Social Europeu
  2. [PID2019-107910RB-I00]
  3. [2017SGR-990]

Ask authors/readers for more resources

The use of low-cost sensors in conjunction with high-precision instrumentation for air pollution monitoring has shown promising results in recent years. However, the quality of the data collected by these sensors has been a major challenge. This paper explores the trade-offs between sensor sampling, calibration quality, and power consumption, and finds that the sampling strategy directly affects the estimation of air pollution quality.
The use of low-cost sensors in conjunction with high-precision instrumentation for air pollution monitoring has shown promising results in recent years. One of the main challenges for these sensors has been the quality of their data, which is why the main efforts have focused on calibrating the sensors using machine learning techniques to improve the data quality. However, there is one aspect that has been overlooked, that is, these sensors are mounted on nodes that may have energy consumption restrictions if they are battery-powered. In this paper, we show the usual sensor data gathering process and we study the existing trade-offs between the sampling of such sensors, the quality of the sensor calibration, and the power consumption involved. To this end, we conduct experiments on prototype nodes measuring tropospheric ozone, nitrogen dioxide, and nitrogen monoxide at high frequency. The results show that the sensor sampling strategy directly affects the quality of the air pollution estimation and that each type of sensor may require different sampling strategies. In addition, duty cycles of 0.1 can be achieved when the sensors have response times in the order of two minutes, and duty cycles between 0.01 and 0.02 can be achieved when the sensor response times are negligible, calibrating with hourly reference values and maintaining a quality of calibrated data similar to when the node is connected to an uninterruptible power supply.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available