4.6 Article

Nanoporous Cauliflower-like Pd-Loaded Functionalized Carbon Nanotubes as an Enzyme-Free Electrocatalyst for Glucose Sensing at Neutral pH: Mechanism Study

Journal

SENSORS
Volume 22, Issue 7, Pages -

Publisher

MDPI
DOI: 10.3390/s22072706

Keywords

cauliflower-like Pd; enzyme-free electrocatalyst; glucose; mechanism; electrodeposition; functionalized carbon nanotubes

Funding

  1. Hubert Curien Program through the PHC MAGHREB Project [19MAG23/41382WC]

Ask authors/readers for more resources

This study proposes a novel nanocatalyst consisting of functionalized carbon nanotubes supporting nanoporous cauliflower-like Pd nanostructures for enzyme-free glucose electrooxidation reaction in a neutral medium. The nanocatalyst was prepared using a cost-effective and straightforward method, and the parameters affecting its morphology, structure, and catalytic properties were investigated. The nanocatalyst exhibited a wide linear range, high sensitivity, and low detection limit for glucose, and it also possessed fast response, low cost, reusability, and poison-free characteristics.
In this work, we propose a novel functionalized carbon nanotube (f-CNT) supporting nanoporous cauliflower-like Pd nanostructures (PdNS) as an enzyme-free interface for glucose electrooxidation reaction (GOR) in a neutral medium (pH 7.4). The novelty resides in preparing the PdNS/f-CNT biomimetic nanocatalyst using a cost-effective and straightforward method, which consists of drop-casting well-dispersed f-CNTs over the Screen-printed carbon electrode (SPCE) surface, followed by the electrodeposition of PdNS. Several parameters affecting the morphology, structure, and catalytic properties toward the GOR of the PdNS catalyst, such as the PdCl2 precursor concentration and electrodeposition conditions, were investigated during this work. The electrochemical behavior of the PdNS/f-CNT/SPCE toward GOR was investigated through Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), and amperometry. There was also a good correlation between the morphology, structure, and electrocatalytic activity of the PdNS electrocatalyst. Furthermore, the LSV response and potential-pH diagram for the palladium-water system have enabled the proposal for a mechanism of this GOR. The proposed mechanism would be beneficial, as the basis, to achieve the highest catalytic activity by selecting the suitable potential range. Under the optimal conditions, the PdNS/f-CNT/SPCE-based biomimetic sensor presented a wide linear range (1-41 mM) with a sensitivity of 9.3 mu A cm(-2) mM(-1) and a detection limit of 95 mu M (S/N = 3) toward glucose at a detection potential of +300 mV vs. a saturated calomel electrode. Furthermore, because of the fascinating features such as fast response, low cost, reusability, and poison-free characteristics, the as-proposed electrocatalyst could be of great interest in both detection systems (glucose sensors) and direct glucose fuel cells.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available