4.3 Review

Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Ultrasound-based sensors for respiratory motion assessment in multimodality PET imaging

Bruno Madore et al.

Summary: Breathing motion is a primary factor limiting image quality in medical imaging and can complicate image fusion from different modalities. Currently available devices for monitoring breathing motion indirectly detect changes in torso outline. We have developed small ultrasound-based sensors that attach to the skin and provide rich motion-sensitive information, presenting a relatively inexpensive hardware solution for respiration monitoring.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Review Engineering, Biomedical

PET respiratory motion correction: quo vadis?

F. Lamare et al.

Summary: This article provides a comprehensive overview of the development in the field of PET respiratory motion correction, covering different multimodality imaging devices and approaches including synchronization, estimation, and motion correction.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

MR-assisted PET respiratory motion correction using deep-learning based short-scan motion fields

Sihao Chen et al.

Summary: The impact of PET respiratory motion correction (MoCo) was evaluated using MRI-assisted methods in both a phantom and patients with hepatic lesions. The results demonstrated that this approach improved quantitative and qualitative metrics of PET images, as well as lesion conspicuity.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT

Tinsu Pan et al.

Summary: A new automated DDG CT method was developed to address misregistration and tumor motion issues in PET/CT imaging. DDG CT showed greater consistency in selecting end-expiratory phase images compared to the clinical standard of 4D CT. It appeared to be more robust in regions prone to misregistration and tumor motion, and provided improved attenuation correction for DDG PET relative to D4D CT. DDG CT offered the benefits of 4D CT without the need for external device gating, making it a promising tool in PET/CT imaging.

MEDICAL PHYSICS (2022)

Article Engineering, Biomedical

Impact of acquisition time and misregistration with CT on data-driven gated PET

M. Allan Thomas et al.

Summary: This study assessed the impact of PET acquisition time and CT misregistration on data-driven gating (DDG) results. The results showed that the acquisition time of DDG-PET had a significant effect on SUVmax and CNR, and the use of DDG-PET/CT further increased SUVmax and CNR. This suggests that accurate registration with DDG-CT is equally important for improving DDG-PET/CT results.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical evaluation of data-driven respiratory gating for PET/CT in an oncological cohort of 149 patients: impact on image quality and patient management

Michael Messerli et al.

Summary: The study evaluated the impact of DDG on PET image quality, lesion detection, and patient management, revealing that DDG provided reliable motion correction and changed clinical management in a considerable number of patients. DDG enables routine use of PET/CT with respiratory gating in clinical practice without the need for external gating equipment.

BRITISH JOURNAL OF RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A data-driven respiratory motion estimation approach for PET based on time-of-flight weighted positron emission particle tracking

Tasmia Rahman Tumpa et al.

Summary: A new TOF-PEPT algorithm is introduced in this paper for specific respiratory motion estimation in PET/CT imaging. Results show high correlation between motion signals derived from TOF-PEPT and Anzai band, outperforming COM methods. Gated imaging based on TOF-PEPT improves image quality, with higher max SUVs and sharper images observed in clinical studies compared to Anzai and COM methods.

MEDICAL PHYSICS (2021)

Article Oncology

Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries

Hyuna Sung et al.

Summary: The global cancer burden in 2020 saw an estimated 19.3 million new cancer cases and almost 10.0 million cancer deaths. Female breast cancer surpassed lung cancer as the most commonly diagnosed cancer, while lung cancer remained the leading cause of cancer death. These trends are expected to rise in 2040, with transitioning countries experiencing a larger increase compared to transitioned countries due to demographic changes and risk factors associated with globalization and a growing economy. Efforts to improve cancer prevention measures and provision of cancer care in transitioning countries will be crucial for global cancer control.

CA-A CANCER JOURNAL FOR CLINICIANS (2021)

Article Oncology

FDG-PET Radiomics for Response Monitoring in Non-Small-Cell Lung Cancer Treated with Radiation Therapy

Montserrat Carles et al.

Summary: This study aims to identify clinically relevant image feature (IF) changes during chemoradiation in NSCLC patients. By utilizing IF variability observed across 4D PET scans as a patient-specific normalization factor, statistically relevant IF changes during treatment are emphasized. Changes in deltaAUCCSH within the primary tumor during treatment can discriminate patients with and without LR, and this could be recommended for monitoring treatment response in NSCLC patients.

CANCERS (2021)

Article Oncology

New Data-Driven Gated PET/CT Free of Misregistration Artifacts

Tinsu Pan et al.

Summary: A new data-driven gated positron emission tomography (PET)/computed tomography (CT) approach was developed to improve registration accuracy. The study showed that cine CT had lower scan coverage and effective radiation dose compared to repeat PET/CT, and using cine CT saved scan time by not requiring repeat PET. The DDG PET/CT method improved registration and quantification, reducing misregistration artifacts and enhancing image quality.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Data-driven gated PET/CT: implications for lesion segmentation and quantitation

M. Allan Thomas et al.

Summary: The study assessed the effects of a new DDG-PET/CT method on PET quantitation and lesion segmentation, finding that compared to baseline PET/CT, PET/ACT, DDG-PET, and DDG-PET/CT had median changes in SUVmax of 20%, 26%, and 66%, respectively. Different correction methods led to changes in lesion volume, LG, centroid-to-centroid distance, and DICE coefficients.

EJNMMI PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory Motion Detection and Correction for MR Using the Pilot Tone Applications for MR and Simultaneous PET/MR Examinations

Thomas Vahle et al.

INVESTIGATIVE RADIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical Evaluation of a Data-Driven Respiratory Gating Algorithm for Whole-Body PET with Continuous Bed Motion

Florian Buether et al.

JOURNAL OF NUCLEAR MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT

James J. Hamill et al.

JOURNAL OF NUCLEAR MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical 18F-FDG PET/CT

Matthew D. Walker et al.

JOURNAL OF NUCLEAR MEDICINE (2020)

Article Engineering, Biomedical

Motion correction of respiratory-gated PET images using deep learning based image registration framework

Tiantian Li et al.

PHYSICS IN MEDICINE AND BIOLOGY (2020)

Article Engineering, Biomedical

Data-driven respiratory gating based on localized diaphragm sensing in TOF PET

Kyungsang Kim et al.

PHYSICS IN MEDICINE AND BIOLOGY (2020)

Review Pharmacology & Pharmacy

Respiratory Gating and the Performance of PET/CT in Pulmonary Lesions

Cinzia Crivellaro et al.

CURRENT RADIOPHARMACEUTICALS (2020)

Article Multidisciplinary Sciences

Estimation of optimal number of gates in dual gated 18F-FDG cardiac PET

R. Klen et al.

SCIENTIFIC REPORTS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of a Novel Elastic Respiratory Motion Correction Algorithm on Quantification and Image Quality in Abdominothoracic PET/CT

Joseph G. Meier et al.

JOURNAL OF NUCLEAR MEDICINE (2019)

Review Oncology

Comparing and contrasting predictive biomarkers for immunotherapy and targeted therapy of NSCLC

D. Ross Camidge et al.

NATURE REVIEWS CLINICAL ONCOLOGY (2019)

Article Engineering, Biomedical

Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images

Joseph G. Meier et al.

PHYSICS IN MEDICINE AND BIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Gated 18F-FDG PET/CT of the Lung Using a Respiratory Spirometric Gating Device: A Feasibility Study

Cyril Jaudet et al.

JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY (2019)

Review Medicine, General & Internal

Molecular heterogeneity in lung cancer: from mechanisms of origin to clinical implications

Federica Zito Marino et al.

INTERNATIONAL JOURNAL OF MEDICAL SCIENCES (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Impact of tumour motion compensation and delineation methods on FDG PET-based dose painting plan quality for NSCLC radiation therapy

Hannah Mary Thomas et al.

JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Ability of FDG PET and CT radiomics features to differentiate between primary and metastatic lung lesions

Margarita Kirienko et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Developing and validating a novel metabolic tumor volume risk stratification system for supplementing non-small cell lung cancer staging

Yonglin Pu et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2018)

Article Computer Science, Interdisciplinary Applications

Self-Gating: An Adaptive Center-of-Mass Approach for Respiratory Gating in PET

Tao Feng et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data

Yihuan Lu et al.

JOURNAL OF NUCLEAR MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Data-driven gating in PET: Influence of respiratory signal noise on motion resolution

Florian Buether et al.

MEDICAL PHYSICS (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Benefits of respiratory-gated 18F-FDG PET acquisition in lung disease

Pascal Bailly et al.

NUCLEAR MEDICINE COMMUNICATIONS (2018)

Review Radiology, Nuclear Medicine & Medical Imaging

Image-guided adaptive radiotherapy in patients with locally advanced non-small cell lung cancer: the art of PET

Willem Grootjans et al.

QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2018)

Article Engineering, Biomedical

Significance of the impact of motion compensation on the variability of PET image features

M. Carles et al.

PHYSICS IN MEDICINE AND BIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Metabolic tumor burden quantified on [18F]FDG PET/CT improves TNM staging of lung cancer patients

Paula Lapa et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2017)

Article Engineering, Biomedical

Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution

Silin Ren et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Multidisciplinary Sciences

PET Radiomics in NSCLC: state of the art and a proposal for harmonization of methodology

M. Sollini et al.

SCIENTIFIC REPORTS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

The Impact of Optimal Respiratory Gating and Image Noise on Evaluation of Intratumor Heterogeneity on 18F-FDG PET Imaging of Lung Cancer

Willem Grootjans et al.

JOURNAL OF NUCLEAR MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Repeatability of Radiomic Features in Non-Small-Cell Lung Cancer [18F]FDG-PET/CT Studies: Impact of Reconstruction and Delineation

Floris H. P. van Velden et al.

MOLECULAR IMAGING AND BIOLOGY (2016)

Article Engineering, Biomedical

Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

Faraz Kalantari et al.

PHYSICS IN MEDICINE AND BIOLOGY (2016)

Article Engineering, Biomedical

Joint PET-MR respiratory motion models for clinical PET motion correction

Richard Manber et al.

PHYSICS IN MEDICINE AND BIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET

Adam Leon Kesner et al.

RADIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Improving the Spatial Alignment in PET/CT Using Amplitude-Based Respiration-Gated PET and Respiration-Triggered CT

Charlotte S. van der Vos et al.

JOURNAL OF NUCLEAR MEDICINE (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications

Hadi Fayad et al.

JOURNAL OF NUCLEAR MEDICINE (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

A contactless approach for respiratory gating in PET using continuous-wave radar

Thomas Ersepke et al.

MEDICAL PHYSICS (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

Mirco Hess et al.

MEDICAL PHYSICS (2015)

Review Oncology

PET in the management of locally advanced and metastatic NSCLC

Willem Grootjans et al.

NATURE REVIEWS CLINICAL ONCOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory-gated imaging in metabolic evaluation of small solitary pulmonary nodules: 18F-FDG PET/CT and correlation with histology

Karim Farid et al.

NUCLEAR MEDICINE COMMUNICATIONS (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

Ronald Boellaard et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Accuracy of amplitude-based respiratory gating for PET/CT in irregular respirations

Yuji Tsutsui et al.

ANNALS OF NUCLEAR MEDICINE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results

Luca Guerra et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Amplitude-based optimal respiratory gating in positron emission tomography in patients with primary lung cancer

Willem Grootjans et al.

EUROPEAN RADIOLOGY (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of a Free-Breathing CT and an Expiratory Breath-Hold CT with Regard to Spatial Alignment of Amplitude-Based Respiratory-Gated PET and CT Images

Charlotte S. van der Vos et al.

JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY (2014)

Article Oncology

PET Motion Compensation for Radiation Therapy Using a CT-Based Mid-Position Motion Model: Methodology and Clinical Evaluation

Matthijs F. Kruis et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2013)

Article Oncology

Motion-specific internal target volumes for FDG-avid mediastinal and hilar lymph nodes

James M. Lamb et al.

RADIOTHERAPY AND ONCOLOGY (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions

Luca Guerra et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2012)

Article Medicine, General & Internal

Non-Small Cell Lung Cancer: Epidemiology, Risk Factors, Treatment, and Survivorship

Julian R. Molina et al.

MAYO CLINIC PROCEEDINGS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours

Wouter van Elmpt et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2011)

Article Oncology

Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

Michalis Aristophanous et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Automatic tumour volume delineation in respiratory-gated PET images

Jayavardhana Gubbi et al.

JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

A novel respiratory tracking system for smart-gated PET acquisition

S. A. Nehmeh et al.

MEDICAL PHYSICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Generating lung tumor internal target volumes from 4D-PET maximum intensity projections

J. M. Lamb et al.

MEDICAL PHYSICS (2011)

Article Engineering, Biomedical

Extension of a data-driven gating technique to 3D, whole body PET studies

Paul J. Schleyer et al.

PHYSICS IN MEDICINE AND BIOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Value of 4-Dimensional 18F-FDG PET/CT in the Classification of Pulmonary Lesions

Ana Maria Garcia Vicente et al.

JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

18F-FDG PET-CT respiratory gating in characterization of pulmonary lesions: approximation towards clinical indications

A. M. Garcia Vicente et al.

ANNALS OF NUCLEAR MEDICINE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical Evaluation

Guoping Chang et al.

JOURNAL OF NUCLEAR MEDICINE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Quiescent period respiratory gating for PET/CT

Chi Liu et al.

MEDICAL PHYSICS (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

The effect of 18F-FDG-PET/CT respiratory gating on detected metabolic activity in lung lesions

Andrea Lupi et al.

ANNALS OF NUCLEAR MEDICINE (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

List Mode-Driven Cardiac and Respiratory Gating in PET

Florian Buether et al.

JOURNAL OF NUCLEAR MEDICINE (2009)

Article Engineering, Biomedical

Retrospective data-driven respiratory gating for PET/CT

Paul J. Schleyer et al.

PHYSICS IN MEDICINE AND BIOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions

Loic Fin et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2008)

Article Computer Science, Interdisciplinary Applications

Respiratory motion correction in 3-D PET data with advanced optical flow algorithms

Mohammad Dawood et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2008)

Article Engineering, Electrical & Electronic

A Novel Method for Respiratory Motion Gated With Geometric Sensitivity of the Scanner in 3D PET

Jianfeng He et al.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Iterative sorting for four-dimensional CT images based on internal anatomy motion

Rongping Zeng et al.

MEDICAL PHYSICS (2008)

Article Engineering, Biomedical

List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations

F. Lamare et al.

PHYSICS IN MEDICINE AND BIOLOGY (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes

Mohammad Dawood et al.

MEDICAL PHYSICS (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Postacquisition detection of tumor motion in the lung and upper abdomen using list-mode PET data:: A feasibility study

Ralph A. Bundschuh et al.

JOURNAL OF NUCLEAR MEDICINE (2007)

Article Engineering, Biomedical

Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans

JWH Wolthaus et al.

PHYSICS IN MEDICINE AND BIOLOGY (2005)

Article Radiology, Nuclear Medicine & Medical Imaging

PET-CT image co-registration in the thorax: influence of respiration

GW Goerres et al.