4.4 Article

Optimizing the performance of solar panel cooling apparatus by application of response surface methodology

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/09544062221101828

Keywords

tilt angle; surface azimuth angle; solar panel; solar panel cooling; optimization; exergy

Funding

  1. All India Council for Technical Education [1-5736521897]

Ask authors/readers for more resources

In this research paper, the efficiency and temperature of solar panels with water cooling arrangements were optimized using experimental data and model equations. The best input parameters were determined as solar flux of 705 W/m², water inlet velocity of 0.7263 m/s, and atmospheric temperature of 32.87 degrees C. The optimized responses showed good agreement with predicted values and previous research.
The high temperature of the solar photovoltaic module reduced the power output and efficiency of the solar panel. Water cooling is one of the best options for reducing the temperature of solar panels. In this research paper, an experimental setup of solar panel with water cooling arrangements has been developed and optimized. The measured experimental data and data generated by model equations have been optimized by the Response Surface Methodology (RSM) tool in the Design of Experiment. The optimized responses are the efficiency of solar panels, module temperature (MT) of solar panel, and exergetic efficiency. The main input parameters solar flux, water inlet velocity, and atmospheric temperature varied from 600 W/m(2) to 1000 W/m(2), 0.5 to 0.9 m/s, and 25 degrees C to 45 degrees C, respectively. The best set of input parameters after optimization in RSM is 705 W/m(2) solar flux, 0.7263 m/s water inlet velocity, and 32.87 degrees C atmospheric temperature on which the values of responses MT, exergetic efficiency and solar panel efficiency are 48.98 degrees C, 19.18 %, and 18.88 % respectively. The experimental setup of solar panel cooling has been run on these input parameters setting and responses are validated with the predicted value of the RSM and the previous research. The calculated percentage error in MT is 2.41%, solar panel efficiency is 1.62%, and exergetic efficiency is 3.82%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available