4.6 Article

Relating 18F-FDG image signal-to-noise ratio to time-of-flight noise-equivalent count rate in total-body PET using the uEXPLORER scanner

Journal

PHYSICS IN MEDICINE AND BIOLOGY
Volume 67, Issue 12, Pages -

Publisher

IOP Publishing Ltd
DOI: 10.1088/1361-6560/ac72f1

Keywords

total-body PET; time-of-flight; noise-equivalent count rate

Funding

  1. NIH [R01 CA249422, R01 CA206187]

Ask authors/readers for more resources

This study assessed the relationship between image signal-to-noise ratio (SNR) and total-body noise-equivalent count rate (NECR) in a long axial field-of-view total-body PET system, and found that TOF-NECR may be a more accurate predictor of SNR for TOF-reconstructed images.
Objective. This work assessed the relationship between image signal-to-noise ratio (SNR) and total-body noise-equivalent count rate (NECR)-for both non-time-of-flight (TOF) NECR and TOF-NECR-in a long uniform water cylinder and 14 healthy human subjects using the uEXPLORER total-body PET/CT scanner. Approach. A TOF-NEC expression was modified for list-mode PET data, and both the non-TOF NECR and TOF-NECR were compared using datasets from a long uniform water cylinder and 14 human subjects scanned up to 12 h after radiotracer injection. Main results. The TOF-NECR for the uniform water cylinder was found to be linearly proportional to the TOF-reconstructed image SNR2 in the range of radioactivity concentrations studied, but not for non-TOF NECR as indicated by the reduced R (2) value. The results suggest that the use of TOF-NECR to estimate the count rate performance of TOF-enabled PET systems may be more appropriate for predicting the SNR of TOF-reconstructed images. Significance. Image quality in PET is commonly characterized by image SNR and, correspondingly, the NECR. While the use of NECR for predicting image quality in conventional PET systems is well-studied, the relationship between SNR and NECR has not been examined in detail in long axial field-of-view total-body PET systems, especially for human subjects. Furthermore, the current NEMA NU 2-2018 standard does not account for count rate performance gains due to TOF in the NECR evaluation. The relationship between image SNR and total-body NECR in long axial FOV PET was assessed for the first time using the uEXPLORER total-body PET/CT scanner.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available