4.4 Article

Dynamic contrast-enhanced MRI parametric mapping using high spatiotemporal resolution Golden-angle RAdial Sparse Parallel MRI and iterative joint estimation of the arterial input function and pharmacokinetic parameters

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Deterministic Arterial Input Function selection in DCE-MRI for automation of quantitative perfusion calculation of colorectal cancer

Christian Toennes et al.

Summary: The deterministic algorithm developed in this study successfully detects the Arterial Input Function in DCEMRI of colorectal cancer with a lower error rate compared to algorithms from literature. The algorithm also produces reproducible results and supports robust and comparable perfusion analysis.

MAGNETIC RESONANCE IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Impact of (k,t) sampling on DCE MRI tracer kinetic parameter estimation in digital reference objects

Yannick Bliesener et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of the Relaxivities of Macrocyclic Gadolinium-Based Contrast Agents in Human Plasma at 1.5, 3, and 7 T, and Blood at 3 T

Pavol Szomolanyi et al.

INVESTIGATIVE RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Blind deconvolution estimation of an arterial input function for small animal DCE-MRI

Radovan Jirik et al.

MAGNETIC RESONANCE IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Vastly accelerated linear least-squares fitting with numerical optimization for dual-input delay-compensated quantitative liver perfusion mapping

Ramin Jafari et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimization of Two-Compartment-Exchange- Model Analysis for Dynamic Contrast-Enhanced MRI Incorporating Bolus Arrival Time

Guy Nadav et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of actual with default hematocrit value in dynamic contrast enhanced MR perfusion quantification in grading of human glioma

Prativa Sahoo et al.

MAGNETIC RESONANCE IMAGING (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

T1 in high-grade glioma and the influence of different measurement strategies on parameter estimations in DCE-MRI

Christopher Larsson et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Models and methods for analyzing DCE-MRI: A review

Fahmi Khalifa et al.

MEDICAL PHYSICS (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Overview of Dynamic Contrast-Enhanced MRI in Prostate Cancer Diagnosis and Management

Sadhna Verma et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Correction of arterial input function in dynamic contrast-enhanced MRI of the liver

Hesheng Wang et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2012)

Review Oncology

Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies

James P. B. O'Connor et al.

NATURE REVIEWS CLINICAL ONCOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

A general dual-bolus approach for quantitative DCE-MRI

Lucy E. Kershaw et al.

MAGNETIC RESONANCE IMAGING (2011)

Article Computer Science, Interdisciplinary Applications

Robust smoothing of gridded data in one and higher dimensions with missing values

Damien Garcia

COMPUTATIONAL STATISTICS & DATA ANALYSIS (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Reconstruction of dynamic contrast enhanced magnetic resonance imaging of the breast with temporal constraints

Liyong Chen et al.

MAGNETIC RESONANCE IMAGING (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Dynamic Contrast-Enhanced MRI in Ovarian Cancer: Initial Experience at 3 Tesla in Primary and Metastatic Disease

Andrew N. Priest et al.

MAGNETIC RESONANCE IN MEDICINE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory

Haoyu Wang et al.

MEDICAL PHYSICS (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Dynamic contrast-enhanced MRI for prostate cancer localization

A. S. N. Jackson et al.

BRITISH JOURNAL OF RADIOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Temporal Sampling Requirements for Reference Region Modeling of DCE-MRI Data in Human Breast Cancer

Catherine R. Planey et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Model-Based Blind Estimation of Kinetic Parameters in Dynamic Contrast Enhanced (DCE)-MRI

Jacob U. Fluckiger et al.

MAGNETIC RESONANCE IN MEDICINE (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Reproducibility Assessment of a Multiple Reference Tissue Method for Quantitative Dynamic Contrast Enhanced-MRI Analysis

Cheng Yang et al.

MAGNETIC RESONANCE IN MEDICINE (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Scan-rescan variability in perfusion assessment of tumors in MRI using both model and data-derived arterial input functions

Edward Ashton et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI

Hai-Ling Margaret Cheng

JOURNAL OF MAGNETIC RESONANCE IMAGING (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Multiple reference tissue method for contrast agent arterial input function estimation

Cheng Yang et al.

MAGNETIC RESONANCE IN MEDICINE (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

New algorithm for quantifying vascular changes in dynamic contrast-enhanced MRI independent of absolute T1 values

E. Mark Haacke et al.

MAGNETIC RESONANCE IN MEDICINE (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data

Thomas E. Yankeelov et al.

MAGNETIC RESONANCE IN MEDICINE (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI

Geoff J. M. Parker et al.

MAGNETIC RESONANCE IN MEDICINE (2006)

Article Endocrinology & Metabolism

Model selection in magnetic resonance imaging measurements of vascular permeability: Gadomer in a 9L model of rat cerebral tumor

JR Ewing et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2006)

Article Radiology, Nuclear Medicine & Medical Imaging

MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results

CMJ de Bazelaire et al.

RADIOLOGY (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

Semiquantitative analysis of dynamic contrast enhanced MRI in cancer patients: Variability and changes in tumor tissue over time

M Medved et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

Measuring the arterial input function with gradient echo sequences

MJP van Osch et al.

MAGNETIC RESONANCE IN MEDICINE (2003)

Article Engineering, Biomedical

Estimation of kinetic parameters without input functions: Analysis of three methods for multichannel blind identification

DY Riabkov et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2002)