4.6 Article

Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode

Journal

MOLECULES
Volume 27, Issue 9, Pages -

Publisher

MDPI
DOI: 10.3390/molecules27092986

Keywords

naproxen; chiral separation; method optimization; polysaccharide stationary phase; reversed-phase HPLC; experimental design

Funding

  1. Janos Bolyai Research Scholarship of the Hungarian Academy of Sciences
  2. Semmelweis University School of PhD Studies [EFOP-3.6.3-VEKOP-16-2017-00009]
  3. Ministry for Innovation and Technology
  4. University of Medicine, Pharmacy, Science and Technology George Emil Palade of Targu Mures Research [511/3/17.01.2022, 10127/3/17.12.2020]

Ask authors/readers for more resources

A novel reversed-phase chiral HPLC method was developed for the enantiopurity control analysis of naproxen. The method utilized a polysaccharide-type chiral stationary phase and different mobile phase compositions to optimize the enantiomer separation.
A novel, validated, reversed-phase (RP), chiral high performance liquid chromatography (HPLC) method was developed for the enantiopurity control analysis of naproxen, a frequently used non-steroidal anti-inflammatory agent using polysaccharide-type chiral stationary phase (CSP). In the screening phase of method development, seven columns were tested in polar organic (PO) mode using mobile phases consisting of 0.1% acetic acid in methanol, ethanol, 2-propanol, and acetonitrile. Enantiorecognition was observed only in five cases. The best enantioseparation was observed on a Lux Amylose-1 column with 0.1% (v/v) acetic acid in ethanol with a resolution (R-s) of 1.24. The enantiomer elution order was unfavorable, as the distomer eluted after the eutomer. When the ethanolic mobile phase was supplemented with water, enantiomer elution order reversal was observed, indicating a difference in the enantiorecognition mechanism upon switching from PO to RP mode. Furthermore, by changing ethanol to methanol, not only lower backpressure, but also higher resolution was obtained. Subsequent method optimization was performed using a face-centered central composite design (FCCD) to achieve higher chiral resolution in a shorter analysis time. Optimized parameters offering baseline separation were as follows: Lux Amylose-1 stationary phase, thermostated at 40 degrees C, and a mobile phase consisting of methanol:water:acetic acid 85:15:0.1 (v/v/v), delivered with 0.65 mL/min flow rate. Using these optimized parameters, a R-s = 3.21 +/- 0.03 was achieved within seven minutes. The optimized method was validated according to the ICH guidelines and successfully applied for the analysis of different pharmaceutical preparations, such as film-coated tablets and gel, as well as fixed-dose combination tablets, containing both naproxen and esomeprazole.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available