4.4 Article

Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices

Journal

JOURNAL OF NEUROSURGERY-SPINE
Volume 37, Issue 4, Pages 556-562

Publisher

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/2022.2.SPINE22143

Keywords

cervical disc arthroplasty; total disc arthroplasty; cervical disc replacement; range of motion; cervical; spine; M6-C; Mobi-C; PCM; ProDisc-C; spine surgery

Ask authors/readers for more resources

Total disc arthroplasty (TDA) is an effective and safe treatment for cervical degenerative disc disease. This study evaluated the long-term maintenance of segmental range of motion (ROM) at the operative cervical level across different TDA devices. The results showed that different TDA device brands have different effects on motion preservation, with M6-C and Mobi-C improving ROM while PCM and ProDisc-C leading to greater segmental stiffness.
OBJECTIVE Total disc arthroplasty (TDA) has been shown to be an effective and safe treatment for cervical degenerative disc disease at short- and midterm follow-up. However, there remains a paucity of literature reporting the differences between individual prosthesis designs with regard to device performance. In this study, the authors evaluated the longterm maintenance of segmental range of motion (ROM) at the operative cervical level across a diverse range of TDA devices. METHODS In this study, the authors retrospectively evaluated all consecutive patients who underwent 1- or 2-level cervical TDA between 2005 and 2020 at a single institution. Patients with a minimum of 6 months of follow-up and lateral flexion/extension radiographs preoperatively, 2 months postoperatively, and at final follow-up were included. Radiographic measurements included static segmental lordosis, segmental range of motion (ROM) on flexion/extension, global cervical (C2-7) ROM on flexion/extension, and disc space height. The paired t-test was used to evaluate improvement in radiographic parameters. Subanalysis between devices was performed using one-way ANCOVA. Significance was determined at p < 0.05. RESULTS A total of 85 patients (100 discs) were included, with a mean patient age of 46.01 +/- 8.82 years and followup of 43.56 +/- 39.36 months. Implantations included 22 (22.00%) M6-C, 51 (51.00%) Mobi-C, 14 (14.00%) PCM, and 13 (13.00%) ProDisc-C devices. There were no differences in baseline radiographic parameters between groups. At 2 months postoperatively, PCM provided significantly less segmental lordosis (p = 0.037) and segmental ROM (p = 0.039). At final follow-up, segmental ROM with both the PCM and ProDisc-C devices was significantly less than that with the M6-C and Mobi-C devices (p = 0.015). From preoperatively to 2 months postoperatively, PCM implantation led to a significant loss of lordosis (p < 0.001) and segmental ROM (p = 0.005) relative to the other devices. Moreover, a significantly greater decline in segmental ROM from 2 months postoperatively to final follow-up was seen with ProDiscC, while segmental ROM increased significantly over time with Mobi-C (p = 0.049). CONCLUSIONS Analysis by TDA device brand demonstrated that motion preservation differs depending on disc design. Certain devices, including M6-C and Mobi-C, improve ROM on flexion/extension from preoperatively to postoperatively and continue to increase slightly at final follow-up. On the other hand, devices such as PCM and ProDisc-C contributed to greater segmental stiffness, with a gradual decline in ROM seen with ProDisc-C. Further studies are needed to understand how much segmental ROM is ideal after TDA for preservation of physiological cervical kinematics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available