4.2 Article

Factors Associated With Implant Removal Following Plate-and-Screw Fixation of Isolated Metacarpal Fractures

Journal

JOURNAL OF HAND SURGERY-AMERICAN VOLUME
Volume 48, Issue 7, Pages E1-E8

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.jhsa.2022.01.026

Keywords

Hardware removal; implant; metacarpal fracture; plate; symptomatic hardware

Ask authors/readers for more resources

The proximity of metacarpal plates to adjacent joints is associated with subsequent implant removal. Patients may be counseled about the higher risk of implant removal when periarticular metacarpal plating is performed.
Purpose The incidence of and associated risk factors for implant removal following the plateand-screw fixation of metacarpal shaft fractures have not been well described. The primary objective of our study was to identify implant-related radiographic parameters associated with implant removal in patients treated with the plate-and-screw fixation of isolated, displaced metacarpal fractures at 2 years of follow-up. The secondary objective of our study was to identify patient-related factors associated with implant removal. Methods A retrospective study of all patients who underwent open treatment of a metacarpal fracture with a plate-and-screw construct from January 1, 2000, to April 30, 2019, at 2 level-1 trauma centers was conducted. After the application of exclusion criteria, we identified 138 patients with a single isolated metacarpal fracture of a nonthumb digit treated with open reduction and internal fixation using a plate-and-screw construct. Our study endpoint was the removal of the plate-and-screw construct or a minimum of 2 years of follow-up without the removal of the hardware. Twenty-three patients achieved our study endpoint as determined using their electronic medical records, and 58 additional patients were reached via telephone to confirm their implant removal status. A bivariate analysis was used to screen for factors associated with implant removal, and variables significant in the bivariate screen were included in a multivariable stepwise logistic regression model. Results Twenty-three out of 81 patients (28%) in our final cohort underwent implant removal by the final follow-up visit. In the logistic regression analysis, the distance between the plate and metacarpophalangeal joint, the distance between the plate and carpometacarpal joint, and active smoking were independently associated with implant removal.Conclusions The proximity of metacarpal plates to adjacent joints is associated with subsequent implant removal. Patients may be counseled about the higher risk of implant removal when periarticular metacarpal plating is performed. (J Hand Surg Am. 2023;48(7):739.e1-e8.Copyright (c) 2023 by the American Society for Surgery of the Hand. All rights reserved.) Type of study/level of evidence Prognosis IV.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available