4.7 Article

Highly sensitive determination of capsaicin with tris(2,2'-bipyridyl) ruthenium(II) electrogenerated chemiluminescence

Journal

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
Volume 910, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2022.116169

Keywords

Capsaicinoids; Capsaicin; Dihydrocapsaicin; Nordihydrocapsaicin; Tris(2,2'-bipyridyl)ruthenium(II); Electrogenerated chemiluminescence

Funding

  1. Basic Science Research Program through the National Research Foundation of Korea - Ministry of Education, Science and Technology [NRF-2021R1F1A1062310]

Ask authors/readers for more resources

A highly sensitive electrogenerated chemiluminescence method has been developed for the detection of capsaicin. The method shows a wide linear range and low detection limit, without the need for electrode surface modification. It is a simple, fast, and sensitive method that can be applied for the determination of capsaicin in the food and pharmaceutical industries.
A highly sensitive tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] electrogenerated chemiluminescence (ECL) detection method for the determination of capsaicin has been developed. In this study, capsaicin was worked as a coreactant in the oxidative-reduction pathway of the Ru(bpy)(3)(2+) ECL. The oxidation of Ru(bpy)(3)(2+) together with coreactant capsaicin on a bare glassy carbon electrode at an applied potential of + 1.10 V vs. Ag/AgCl (3 M NaCl) led to a strong ECL emission. The Ru(bpy)(3)(2+) ECL emission of capsaicin was strongly dependent upon the buffer solution pH, in which a strong ECL was obtained in alkaline buffer solution. Under the opti-mized conditions, the present Ru(bpy)(3)(2+) ECL detection method showed a linear response to capsaicin in the linear range from 1.0 x 10(-7) M to 1.0 x 10(-4) M with a limit of detection of 9.4 x 10(-8) M (S/N = 3). In addi-tion, the present method can detect dihydrocapsaicin and nordihydrocapsaicin with a detection limit of 1.9 x 10(-7) M and 2.2 x 10(-7) M, respectively. The present ECL method shows good analytical performance for capsaicinoids in terms of linear dynamic range and detection limit compared to those obtained at other elec-trochemical methods even without the employment of additional modification of electrode surfaces to enhance the detection responses. In addition, no analyte preconcentration was required. The recovery tests performed for spiked capsaicin in real pepper samples were satisfactory with the recovery from 95% to 103%. To the best of our knowledge, this is the first report on the application of ECL for the quantitative determination of cap-saicinoids. Since the present method is very simple, fast and sensitive, it could be applied for the determination of capsaicin in food and pharmaceuticals.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available