4.7 Article

Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry

Journal

Publisher

ELSEVIER
DOI: 10.1016/j.jaap.2022.105447

Keywords

Gas chromatography; mass spectrometry; Disinfectants; Quaternary ammonium compounds; Didecyldimethylammonium chloride (DDAC-C10); Didecyldimethylammonium bromide (DDAB-C10); Pyrolysis

Ask authors/readers for more resources

A rapid and reliable method for detecting quaternary ammonium cation and halide anion in a single analytical run was developed using gas chromatography mass spectrometry (GC/MS). The method allows for the determination of both the cation and anion in disinfectants within seven minutes. The study revealed clear differences in biocidal activity, toxicity, and allergic potential among different halide anions and quaternary ammonium cations.
The use of quaternary ammonium compounds (QACs) as disinfectants has increased tremendously in the COVID19 pandemic to inactivate Severe Acute Respiratory Syndrome Coronavirus type 2 (SARS-CoV2). Dialkyldimethylammonium halides represent a frequently used type among QACs. Different halide anions, each ionically linked to the same quaternary ammonium cation, show clear differences in biocidal activity, toxicity and allergic potential. Likewise, the alkyl chain length at the ammonium cation induces different biocidal efficacy and toxicology. Therefore, the object of this research was to develop a rapid and reliable method for the detection of ammonium cation and halide anion in a single analytical run. For that purpose, a gas chromatography mass spectrometry (GC/MS) method was developed for QACs of the dialkyldimethylammonium type. Pyrolytic conversion of the QACs in the injector port of the gas chromatograph into volatile molecule species allows fast and reliable subsequent GC/MS analysis. The developed method is suited for the determination of both the quaternary ammonium cation and the corresponding halide anion in a single gas chromatographic run. The application of this method to bulk material and standard material of explicitly specified didecyldimethylammonium chloride revealed deviations from the manufacturer's specifications in a range up to four-fifths. Furthermore, didecyldimethylammonium chloride was detected in a disinfectant that does not comply with the labeling requirement for biocidal ingredients. With the method presented, results can be obtained for disinfectants with minimum effort within seven minutes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available