4.4 Article

Giant Epstein Tester for Magnetic Energy Loss Measurements of Non-Annealed Domain-Refined Fe-Si

Journal

IEEE TRANSACTIONS ON MAGNETICS
Volume 58, Issue 5, Pages -

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMAG.2022.3158473

Keywords

Cutting effects; domain refinement; Epstein tester; magnetic loss; silicon iron

Funding

  1. Austrian Science Fund (FWF) [P31596]
  2. Austrian Science Fund (FWF) [P31596] Funding Source: Austrian Science Fund (FWF)

Ask authors/readers for more resources

This article introduces a new giant Epstein tester for measuring magnetic energy losses. By increasing the strip width and length, and using multiple layers of samples, the problems in the testing process can be reduced and sufficient averaging can be achieved. The results of this tester are similar to those of other testers, but it has some drawbacks, such as the need for more samples and lower absolute accuracy.
Since 100 years, the Epstein tester serves as a compact and simple apparatus for the measurement of magnetic energy losses, in particular for Fe-Si steel. However, drawbacks result from time-consuming cutting and stacking of the high number of just W = 3 cm wide sample strips of the standard Epstein tester (SET). Furthermore, the effects of cutting result in increased losses. Needs of annealing impede tests of modern materials with domain refinement that may lose its effectiveness. Results of numerical modeling indicated that both problems can be reduced by a strong enlargement of the strip width. Here, we report a novel giant Epstein tester (GET) with W = 10 cm, in combination with increased strip length L = 65 cm. Sufficient averaging over test material is attained with two layers, i.e., from just eight strips. The magnetic field strength is determined by four large 3-D-printed tangential field coils, excluding impact from the four corners of frame. Time-averaged loss P is computed from instantaneous magnetization power values p, offering also maximum loss and orientation power. Results of GET were compared to data from single-sheet tester (SST) data, proving close similarities, without needs of annealing which is significant for laser scribed steel, as tested here. Results from SET prove to be higher. Analysis of power p indicates the impact of supplementary domains in the magnetization process of the scribed material. Compared to SST, the drawbacks of the GET are the need of eight sample strips, as well as lower absolute accuracy, due to higher inhomogeneity. On the other hand, advantages are the absence of a yoke system and simplicity of test apparatus.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available