A Mismatch Correction Method for Electrode Offset in Electrical Impedance Tomography

Journal

IEEE SENSORS JOURNAL
Volume 22, Issue 7, Pages 7248-7257

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2022.3155476

Keywords

Electrodes; Image reconstruction; Electrical impedance tomography; Voltage measurement; Electric potential; Sensitivity; Conductivity; Electrical impedance tomography; electrode offset; mismatch correction; reconstruction

Funding

  1. National Natural Science Foundation of China [61903127, 51837011, 61771475, U1904182]
  2. Postdoctoral Science Foundation of China [2020M673664]
  3. Foundation for University Key Young Teacher by Henan Province of China [2020GGJS061]
  4. Scientific and Technological Innovation Program for Universities in Henan Province of China [21HASTIT018]
  5. Scientific Research Project for Postgraduates of Henan Normal University of China [YL202105]

Ask authors/readers for more resources

This paper proposes a novel method to improve the reconstruction quality of electrical impedance tomography (EIT) in case of electrode offset. By correcting the mismatched boundary voltage caused by electrode movement, and conducting image reconstruction with total generalized variation regularization method, the proposed method effectively improves the image quality under electrode offset. The method is potential for mismatch correction in some medical applications, as demonstrated by extensive experiments.
Electrical impedance tomography (EIT) has attracted research interests in imaging of brain function, detection of breast cancer, monitoring of lung function and other medical fields. For EIT, its image reconstruction is largely affected by variation of electrode placement arranged around the detected object. Note that electrode offset is unavoidable in some medical applications, leading to low-quality reconstructed images or even failure of reconstruction. In this paper, a novel method is proposed to improve reconstruction quality in case of electrode offset. By identifying which electrode moves, mismatched boundary voltage caused by movement of electrode is corrected. After mismatch correction, image reconstruction is conducted with total generalized variation regularization method. To demonstrate performance of the proposed method in suppressing impact of electrode offset on reconstruction, extensive work is carried out. Mismatch corrections for four models under a series of counterclockwise or clockwise movements of a certain electrode are studied. The reconstruction results show that the proposed method can effectively improve the image quality under electrode offset. Even in presence of larger electrode offset and noise, reconstructed images have been greatly improved. Quantitative evaluation is also conducted by calculating relative blur radius (RBR). It is shown that RBR values are much closer to 1 compared with results under mismatch conditions. Image reconstruction when two electrodes move is also investigated which further validate the performance of the proposed method. This method is potential for mismatch correction in some medical applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available