4.8 Article

Impact of Artificial Intelligence on Miss Rate of Colorectal Neoplasia

Journal

GASTROENTEROLOGY
Volume 163, Issue 1, Pages 295-+

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1053/j.gastro.2022.03.007

Keywords

Colorectal Cancer; Artificial Intelligence; Miss Rate; Tandem Colonoscopy; Adenoma Miss Rate

Funding

  1. Cosmo Artificial Intelligence-AI Ltd.

Ask authors/readers for more resources

This study demonstrates that the use of artificial intelligence can significantly reduce the miss rate of colorectal neoplasia, especially for small and subtle lesions. This is of great importance in improving the prevention of colorectal cancer.
BACKGROUND & AIMS: Artificial intelligence (AI) may detect colorectal polyps that have been missed due to perceptual pitfalls. By reducing such miss rate, AI may increase the detection of colorectal neoplasia leading to a higher degree of colorectal cancer (CRC) prevention. METHODS: Patients undergoing CRC screening or surveillance were enrolled in 8 centers (Italy, UK, US), and randomized (1:1) to undergo 2 same-day, back-to-back colonoscopies with or without AI (deep learning computer aided diagnosis endoscopy) in 2 different arms, namely AI followed by colonoscopy without AI or vice-versa. Adenoma miss rate (AMR) was calculated as the number of histologically verified lesions detected at second colonoscopy divided by the total number of lesions detected at first and second colonoscopy. Mean number of lesions detected in the second colonoscopy and proportion of false negative subjects (no lesion at first colonoscopy and at least 1 at second) were calculated. Odds ratios (ORs) and 95% confidence intervals (CIs) were adjusted by endoscopist, age, sex, and indication for colonoscopy. Adverse events were also measured. RESULTS: A total of 230 subjects (116 AI first, 114 standard colonoscopy first) were included in the study analysis. AMR was 15.5% (38 of 246) and 32.4% (80 of 247) in the arm with AI and non-AI colonoscopy first, respectively (adjusted OR, 0.38; 95% CI, 0.23-0.62). In detail, AMR was lower for AI first for the <= 5 mm (15.9% vs 35.8%; OR, 0.34; 95% CI, 0.21-0.55) and nonpolypoid lesions (16.8% vs 45.8%; OR, 0.24; 95% CI, 0.13-0.43), and it was lower both in the proximal (18.3% vs 32.5%; OR, 0.46; 95% CI, 0.26-0.78) and distal colon (10.8% vs 32.1%; OR, 0.25; 95% CI, 0.11-0.57). Mean number of adenomas at second colonoscopy was lower in the AI-first group as compared with non-AI colonoscopy first (0.33 +/- 0.63 vs 0.70 +/- 0.97, P < .001). False negative rates were 6.8% (3 of 44 patients) and 29.6% (13 of 44) in the AI and non-AI first arms, respectively (OR, 0.17; 95% CI, 0.05-0.67). No difference in the rate of adverse events was found between the 2 groups. CONCLUSIONS: AI resulted in an approximately 2-fold reduction in miss rate of colorectal neoplasia, supporting AI-benefit in reducing perceptual errors for small and subtle lesions at standard colonoscopy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available