The collaborative study within the EU H2020 OLEUM project aimed at developing a harmonized SPME-GC-MS method for determination of volatile compounds in virgin olive oil showed satisfactory linearity and repeatability. The reproducibility of results varied depending on the compound, with the lowest RSD% values found for three specific compounds. Different quantification methods were studied, with the correction of calibration curves using an internal standard showing slightly worse repeatability but better accuracy and reproducibility.
The requirement for developing an instrumental method for analysis of volatile compounds responsible for the aroma that supports the work of the sensory panel test of virgin olive oils is a matter of great importance. In this paper, five laboratories participated in a collaborative study within the EU H2020 OLEUM project to develop a peer interlaboratory study of a harmonized SPME-GC-MS method for determination of volatile compounds in virgin olive oil responsible for positive attributes (e.g. fruity) and the main sensory defects. Linearity (R-2 > 0.94) and repeatability (mean relative standard deviation, RSD% = 7.60%) were satisfactory. Reproducibility results were uneven depending on the compound. The lowest RSD% values were found for (Z)-3-hexenyl acetate (19.19%), 1-hexanol (13.26%), and acetic acid (17.47%). The limits of quantification were <0.07 mg/kg for all compounds except for (E)-2-decenal and pentanoic acid. The study of different quantification methods revealed that the correction of the calibration curves using the internal standard led to a slightly worse repeatability, but better accuracy and reproducibility. The results obtained by five laboratories are preparatory towards a trial proper validation study, already planned in OLEUM project, involving external labs participating on a voluntary basis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available