4.7 Article

Finite element analyses of FRP-strengthened concrete beams with corroded reinforcement

Journal

ENGINEERING STRUCTURES
Volume 257, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2022.114007

Keywords

Reinforced concrete structures; Finite element analysis; Corrosion; Fibre-reinforced polymer; CFRP; GFRP; Strengthening; Cracks; Interface; U-jacket

Funding

  1. Swedish Transport Administration [BBT-2018-011]

Ask authors/readers for more resources

This paper investigates the flexural behavior of corrosion-damaged reinforced concrete beams strengthened with externally bonded FRP using non-linear finite element analysis. The study found that the modeling of pitting corrosion location, lengths, and number of pits has a significant influence on predicting the load and deformation capacity of beams. Different strengthening methods were effective for different beam geometries and corrosion damages.
Existing deteriorated reinforced concrete (RC) structures need strengthening to extend service life. Fibre reinforced polymer (FRP) has been widely used to strengthen sound structures, but its application on damaged concrete structures still needs to be investigated. This paper presents non-linear finite element analyses conducted to assess the flexural behaviour of corrosion-damaged RC beams strengthened with externally bonded FRP. Beams in four different categories were analysed: a reference beam, a corroded but non-strengthened beam, and corroded beams strengthened with glass FRP (GFRP) and carbon FRP (CFRP) respectively. Furthermore, the strengthened beams were modelled with different modelling choices to investigate the effectiveness of FRP applied to the beam soffit and as U-jackets. Pre-loading and corrosion induced cracks were incorporated by reducing the tensile strength of concrete elements at crack locations. Average and pitting corrosion were incorporated by reducing the cross-sectional area of the reinforcement corresponding to the measured corrosion levels. Interface elements were used to simulate the bond between FRP and concrete. The modelling methods were validated against experimental results. It was found that modelling of pitting corrosion, especially the location of pits, lengths and number of pits considered, were influential in predicting the load and deformation capacity of beams. A CFRP plate at the beam soffit, combined with inclined U-jackets at its ends of the CFRP plate provided sufficient flexural strengthening. Thus, intermediate U-jackets did not further increase the load-bearing capacity for the studied beam geometry and corrosion damages. However, with a GFRP sheet at the beam soffit, both inclined and intermediate U-jackets were needed to provide full utilisation of the GFRP sheet for the studied beam geometry. In further studies of the effectiveness of the strengthening methods, it is recommended to investigate beams of varying dimensions, corrosion patterns and levels, and FRP spacing and dimensions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available