4.7 Article

Demand-oriented differentiated multi-zone thermal environment: Regulating air supply direction and velocity under stratum ventilation

Journal

BUILDING AND ENVIRONMENT
Volume 219, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2022.109242

Keywords

Air distribution; Air supply velocity; Differentiated thermal environment; Multiple subzones; Non-uniform environment

Funding

  1. National Natural Science Foundation of China [51878043]
  2. Beijing Natural Science Foundation [8212012]
  3. Special Fund of Beijing Key Laboratory of Indoor Air Quality Evaluation and Control [BZ0344KF21-01]
  4. Fundamental Research Funds for the Central Universities [FRF-TP-20-001A3]

Ask authors/readers for more resources

This study investigates the achievable difference level of thermal environment in a ventilated room with multiple air supply inlets by independently regulating the air supply directions and velocities from different inlet groups. The results show that regulating air supply direction significantly affects the differentiated thermal environment, with potential for significant Delta PMV between subzones.
Different thermal preferences from occupants in a shared space must be satisfied simultaneously. For a ventilated room with multiple air supply inlets, differentiated thermal environment parameters can be maintained in different subzones by liberating the unified air supply parameter adjustment from all the air supply inlets and subsequently adopting independent adjustment of different groups of air supply inlets near different subzones. In this study, the achievable difference level of thermal environment was investigated numerically based on the stratum ventilation. Primarily, the effect of independently regulating the air supply directions and velocities from two inlet groups on the difference in the local thermal environment between subzones was analyzed. The position of occupants and heat distribution were considered as the influencing factors. Further, the predicted mean vote (PMV) index was utilized to evaluate the cool or warm degree of the local thermal environment while the draught rate (DR) and percentage dissatisfied (PD) indices were utilized to evaluate the local thermal discomfort. The results obtained indicated that regulating air supply direction significantly affected the differentiated thermal environment, with the achievable Delta PMV between subzones up to 1.46. Moreover, the increase in air supply velocity based on the appropriate air supply direction further expanded the Delta PMV. In addition, the change in heat source position resulted in a Delta PMV decrease of 0.36. No strong draught risk and local thermal discomfort caused by the vertical temperature difference were observed. This study is expected to provide guidance for the maintenance of demand-oriented zoning thermal environment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available