4.6 Article

Evaluation of the Nallasamy formula: a stacking ensemble machine learning method for refraction prediction in cataract surgery

Related references

Note: Only part of the references are listed.
Article Ophthalmology

AI-powered effective lens position prediction improves the accuracy of existing lens formulas

Tingyang Li et al.

Summary: This study assessed the use of machine learning to predict postoperative anterior chamber depth (ACD) and integrate the predictions into existing intraocular lens (IOL) calculation formulas. The results showed that using the more accurately predicted postoperative ACD significantly improved the prediction accuracy of the four existing IOL power formulas.

BRITISH JOURNAL OF OPHTHALMOLOGY (2022)

Article Ophthalmology

Accuracy of a new intraocular lens power calculation method based on artificial intelligence

David Carmona Gonzalez et al.

Summary: This study developed and evaluated a new IOL power calculation method based on machine learning techniques, which was found to be the most accurate compared to traditional power calculation formulas. The new method achieved higher accuracy in predicting refractive outcomes for cataract surgery patients.
Article Ophthalmology

Update on Intraocular Lens Power Calculation Study Protocols The Better Way to Design and Report Clinical Trials

Kenneth J. Hoffer et al.

Summary: The text highlights the importance of accuracy in intraocular lens (IOL) power calculation, modernizing and quantifying research protocols and methods to assist researchers in designing and reporting results on IOL power calculation and biometry. Recommendations for improving research accuracy and validity were provided through evaluation and guidance on patient enrollment criteria, formula testing, refraction measurement, and statistical analysis methods.

OPHTHALMOLOGY (2021)

Article Medicine, General & Internal

Use of a Machine Learning Method in Predicting Refraction after Cataract Surgery

Tomofusa Yamauchi et al.

Summary: The study describes the use of machine learning in predicting postoperative refraction after cataract surgery and compares its accuracy to conventional IOL power calculation formulas. While some ML methods had lower prediction errors than conventional formulas, there was no statistically significant difference, indicating that the accuracy of the ML method was not inferior to that of the BU-II formula.

JOURNAL OF CLINICAL MEDICINE (2021)

Article Ophthalmology

The PEARL-DGS Formula: The Development of an Open-source Machine Learning-based Thick IOL Calculation Formula

Guillaume Debellemaniere et al.

Summary: This study describes an open-source, reproducible method for designing IOL calculation formulas and evaluates the formula built using this methodology. The results show that the methodology achieved accuracy comparable to other advanced IOL formulas in terms of consistency and precision.

AMERICAN JOURNAL OF OPHTHALMOLOGY (2021)

Article Ophthalmology

Gender differences in refraction prediction error of five formulas for cataract surgery

Yibing Zhang et al.

Summary: Gender differences were found in optical biometry measurements and lens power calculations. Modern IOL formulas showed significantly different prediction errors for males and females, with males tending to be more hyperopic and females more myopic. Optimization of lens constants by gender can reduce refraction prediction errors for certain modern IOL formulas.

BMC OPHTHALMOLOGY (2021)

Article Ophthalmology

Fifteen years of IOL exchange: indications, outcomes, and complications

Jordy Goemaere et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2020)

Article Computer Science, Information Systems

The Bayesian Additive Regression Trees Formula for Safe Machine Learning-Based Intraocular Lens Predictions

Gerald P. Clarke et al.

FRONTIERS IN BIG DATA (2020)

Article Ophthalmology

Accuracy of Intraocular Lens Calculation Formulas

Ronald B. Melles et al.

OPHTHALMOLOGY (2018)

Article Ophthalmology

Accuracy of 3 new methods for intraocular lens power selection

Jack X. Kane et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2017)

Article Ophthalmology

Intraocular lens power formula accuracy: Comparison of 7 formulas

Jack X. Kane et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2016)

Article Ophthalmology

Indications and Outcomes of Intraocular Lens Exchange During a Recent 5-Year Period

Jason J. Jones et al.

AMERICAN JOURNAL OF OPHTHALMOLOGY (2014)

Letter Ophthalmology

The Effect of Testing Distance on Intraocular Lens Power Calculation

Michael J. Simpson et al.

JOURNAL OF REFRACTIVE SURGERY (2014)

Correction Ophthalmology

The Hoffer Q formula: A comparison of theoretic and regression formulas (vol 19, pg 700, 1993)

K. J. Hoffer

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2007)

Letter Ophthalmology

Errata in printed hoffer Q formula - Reply

Kenneth J. Hoffer

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2007)

Article Ophthalmology

Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis

W Haigis et al.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2000)