4.6 Review

Measurement of quality of recovery after surgery using the 15-item quality of recovery scale: a systematic review and meta-analysis

Journal

BRITISH JOURNAL OF ANAESTHESIA
Volume 128, Issue 6, Pages 1029-1039

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.bja.2022.03.009

Keywords

anaesthesia; outcome; patient centred outcome measure; psychometrics; quality of life; recovery; surgery; validity

Categories

Funding

  1. Australian National Health and Medical Research Council [1159667]

Ask authors/readers for more resources

The QoR-15 is a valid, reliable, and responsive patient-centred outcome measure in surgical patients. It is widely accepted and used in multiple countries and languages, and is highly regarded by both patients and clinicians.
Background: There are very few patient-centred global outcome measures of recovery in the days or weeks after surgery. This meta-analysis evaluated the psychometric properties and clinical acceptability of the 15-item quality of recovery (QoR-15) scale. Methods: We searched bibliographic databases for studies undertaking psychometric evaluation of the QoR-15 or using the QoR-15 as an outcome measure after surgery. Record screening, data extraction, and quality assessments were independently done by two researchers. Weighted averages estimating overall summary statistics across all the studies were calculated using random-effects meta-analysis. Pooled correlation coefficients were transformed using a Fisher z-transformation and then back-transformed to calculate pooled results. The four co-primary endpoints were validity, reliability, responsiveness, and clinical utility of the QoR-15 scale. Results: A total of 26 unique studies met the eligibility criteria, yielding up to 22 847 patients across 16 countries, in 15 languages. A further 172 studies in a further 18 countries and six languages used the QoR-15 as an outcome measure. The QoR-15 had excellent discriminant validity, with the mean difference in QoR-15 scores in patients with and without postoperative complications (9.6; 95% confidence interval [CI], 5.9-13.3; P<0.001), and good convergent validity (for a global visual analogue recovery scale, pooled r=0.63; 95% CI, 0.54-0.71). There was excellent reliability: internal consistency (pooled alpha=0.85; 95% CI, 0.83-0.87), split-half reliability=0.80 (95% CI, 0.75e0.84), and testeretest reliability=0.97 (95% CI, 0.95-0.98). There was also high responsiveness (pooled standardised response mean=0.87; 95% CI, 0.65-1.08), patient recruitment into evaluation studies (96%; 95% CI, 93-99), and excellent completion and return rates (91%; 95% CI, 84-96). The mean time to complete the QoR-15 was 2.7 (95% CI, 2.2-3.1) min. Conclusions: The QoR-15 is a valid, reliable, and responsive patient-centred outcome metric in surgical patients. It is highly acceptable to both patients and clinicians. Registration: Open Science Framework Identifier: DOI 10.17605/OSF.IO/78HTA.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available