4.2 Article

Approaching automated applicator digitization from a new angle: Using sagittal images to improve deep learning accuracy and robustness in high-dose-rate prostate brachytherapy

Journal

BRACHYTHERAPY
Volume 21, Issue 4, Pages 520-531

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.brachy.2022.02.005

Keywords

Deep learning; Applicator digitization; Brachytherapy; Prostate; Segmentation

Ask authors/readers for more resources

This study achieved automated segmentation of treatment applicators in high-dose-rate brachytherapy using deep learning and density-based clustering algorithms. The proposed method demonstrated submillimeter agreement with manual segmentation and showed advantages in geometric accuracy and time efficiency. This automated segmentation approach has the potential to improve treatment quality and consistency while reducing the patient's time under anesthesia.
PURPOSE: To automate the segmentation of treatment applicators on computed tomography (CT) images for high-dose-rate (HDR) brachytherapy prostate patients implanted with titanium needles with the goals of improving plan quality and reducing the patient's time under anesthesia. METHODS: The investigation was performed using 57 retrospective, interstitial prostate treatments randomly assigned to training (n = 27), validation (n = 10), and testing (n = 20). Unique to this work, the CT image set was reformatted into 2D sagittal slices instead of the default axial orientation. A deep learning-based segmentation was performed using a 2D U-Net architecture followed by a density-based linkage clustering algorithm to classify individual catheters in 3D. Potential confounders, such as gold seeds and conjoined applicators with intersecting needle geometries, were corrected using a customized polynomial fitting algorithm. The geometric agreement of the automated digitization was evaluated against the clinically treated manual digitization to measure tip and shaft errors in the reconstruction. RESULTS: The proposed algorithm achieved tip and shaft agreements of-0.1 +/- 0.6 mm (range-1.8 mm to 1.4 mm) and 0.13 +/- 0.09 mm (maximum 0.96 mm), respectively on a data set with 20 patients and 353 total needles. Our method was able to separate all intersecting applicators reliably. The time to generate the automated applicator digitization averaged approximately 1 min. CONCLUSIONS: Using sagittal instead of axial images for 2D segmentation of interstitial brachytherapy applicators produced submillimeter agreement with manual segmentation. The auto-mated digitization of interstitial applicators in prostate brachytherapy has the potential to improve quality and consistency while reducing the patient's time under anesthesia. (C) 2022 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available