4.8 Article

Transient potentiometry based D-serine sensor using engineered D-amino acid oxidase showing quasi-direct electron transfer property

Journal

BIOSENSORS & BIOELECTRONICS
Volume 200, Issue -, Pages -

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113927

Keywords

D-Serine; Transient potentiometry; Open circuit potential; D-Amino acid Oxidase; Direct electron transfer

Funding

  1. Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University
  2. Overseas Challenge Program for Young Research, Japan Society for the Promotion of Science (JSPS), Japan

Ask authors/readers for more resources

This study reports a novel sensing principle for o-serine using transient potentiometry based o-serine sensor with engineered DAAOx. The sensor showed rapid and sensitive signals, suitable for monitoring with different time resolution and concentration ranges.
D-Serine biosensing has been extensively reported based on enzyme sensors using flavin adenine dinucleotide (FAD) -dependent n-amino acid oxidase (DAAOx), based on the monitoring of hydrogen peroxide generated by the enzymatic reaction, which is affected by dissolved oxygen concentration in the measurement environment in in vivo use. Here we report a novel sensing principle for o-serine, transient potentiometry based o-serine sensor using engineered DAAOx showing quasi-direct electron transfer (DET) property. DAAOx Gly52Val mutant, revealed to possess dye-mediated dehydmgenase activity using artificial synthetic electron acceptors, while its oxidase activity was negligible. The enzyme was immobilized on electrode and was modified with amine-reactive phenazine ethosulfate, resulted an enzyme electrode showing quasi-DET type response. Although OCP based monitoring took more than several minutes to obtain steady state OCP value, the time dependent OCP change monitoring, transient potentiometry, provided rapid and sensitive sensor signals. While dOCP/dt based monitoring was suitable for sensing with longer than 5 s time resolution with o-serine concentration range between 0.5 mM and 5 mM, dOCP/d root t based monitoring is suitable for o-serine monitoring with much shorter time resolution (less than 1 s) with high sensitivity with wider dynamic range (20 mu M-30 mM). The maximum dOCP/d root t was -39.2 +/- 2.0 mV/s(1/2), the K-m(app) was 1.9 mM, and the lower limit of detection was 20 mu M. In addition, D-serine monitoring was also possible in the artificial cerebrospinal fluid. The transient potentiometry based sensing reported in this study will be further utilized to realize miniaturized, continuous, real-time, in vivo sensor for o-serine monitoring.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available