The LipoSEARCH System is an innovative method for analyzing lipoprotein subclasses, and a developed internal standard using a pigment has been shown to guarantee simultaneous detection and improve accuracy.
The LipoSEARCH?? System is an innovative lipoprotein class analysis method based on gel-permeation high-performance liquid chromatography (HPLC). This system uses a gel permeation column to separate the major lipoprotein subclasses (chylomicron, very low-density lipoprotein, low-density lipoprotein, and high-density lipoprotein) in serum according to particle size and splits them into two pathways to measure total cholesterol (TC; esterified + unesterified cholesterol) and triglyceride (TG) concentrations simultaneously to obtain chromatograms for each. These chromatograms were analyzed based on the results of the calibration serum by fitting Gaussian curves to profile the 20 lipoprotein subclasses defined in detail. An important assumption of this HPLC system is its simultaneous detection of two pathways to guarantee the accuracy of each analysis. Therefore, in the present study, we investigated the development of an internal standard that can guarantee the simultaneous detection of this system by adding a pigment to the serum. We focused on quinone pigments with absorption at 550 nm, which is the wavelength used for the enzymatic assay of TC and TG concentrations in the system. As a result, we succeeded in producing overlapping pigment peaks that appeared after the analytical chromatograms in two pathways. It is also suggested that the pigment solution as an internal standard is stable in freezing storage and has little effect on the analysis. The developed internal standard is expected to contribute to the accuracy assurance of lipoprotein analysis by this dual-detection HPLC system.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available