4.8 Article

A Demonstration of Broadband Cavity-Enhanced Absorption Spectroscopy at Deep-Ultraviolet Wavelengths: Application to Sensitive Real-Time Detection of the Aromatic Pollutants Benzene, Toluene, and Xylene

Journal

ANALYTICAL CHEMISTRY
Volume 94, Issue 10, Pages 4286-4293

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c04940

Keywords

-

Funding

  1. National Natural Science Foundation of China [91544225, 51776129]
  2. National Key Research and Development Program of China [2017YFC0211504, 2018YFC0213800]

Ask authors/readers for more resources

This study demonstrates the first detection of benzene, toluene, and xylene using incoherent broadband cavity-enhanced absorption spectroscopy. By calibrating the mirror reflectivity and measuring absorption cross sections, the study provides sensitivity and concentration measurement methods, and demonstrates the instrument's ability to quantify complex mixtures.
Benzene, toluene, and xylene (BTX) are serious air pollutants emitted by the chemical industry. Real-time monitoring of these air pollutants would be a valuable tool to regulate emissions of these compounds and reduce the harm they cause to human health. Here, we demonstrate the first detection of BTX using incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS). The instrument was operated in the deep- ultraviolet spectral region between 252 and 286 nm, where aromatic compounds have intense pi-pi* absorption bands. The mirror reflectivity was calibrated by two methods and exceeded 99.63% at 266 nm. At an integration time of 60 s, the 1 sigma measurement sensitivities were estimated to be 7.2 ppbv for benzene, 21.9 ppbv for toluene, 10.2 ppbv for m-xylene, and 4.8 ppbv for p-xylene, respectively. The absorption cross sections of BTX were measured in this work with an uncertainty of 10.0% at a resolution of 0.74 nm. The absorption cross sections reported in this work were in good agreement with those from earlier studies after accounting for differences in spectral resolution. To demonstrate the ability of the instrument to quantify complex mixtures, the concentrations of m-xylene and p-xylene have been retrieved under five different mixing ratios. Instrumental improvements and measurements strategies for use in different applications are discussed.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available