4.7 Article

A molecularly imprinted electrochemical sensor based on surface imprinted polymerization and boric acid affinity for selective and sensitive detection of P-glycoproteins

Journal

ANALYTICA CHIMICA ACTA
Volume 1207, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2022.339797

Keywords

P-glycoprotein; Boric acid affinity; Electrochemical sensor; Molecularly imprinted polymers (MIPs); Surface imprinting polymerization

Funding

  1. Project of Xiamen Innova-tion Fund for Youth [3502Z20206044]
  2. Educa-tional and Scientific Research Project for Young and Middle-Aged Teachers of Fujian Province [JT180012]
  3. Natural Science Foun-dation of Fujian Province, China [2020J01043]

Ask authors/readers for more resources

This study developed a molecular imprinted electrochemical sensor for the selective and sensitive detection of P-glycoprotein. The sensor exhibited excellent selectivity, specificity, storage stability, and reusability. Compared with the ELISA kit method, the sensor showed advantages of wider detection range, shorter detection time, higher accuracy, and lower cost.
In this study, a molecular imprinted electrochemical sensor based on surface imprinting and boric acid affinity was prepared for the selective and sensitive detection of P-glycoprotein (P-gp) under physiological conditions. Several polymerization parameters were systematically investigated. Four electrochemical methods were used to characterize the sensors. It was proved that the glassy carbon electrode (GCE) was well modified by molecularly imprinted polymers (MIPs), and the electrochemical detection results were consistent with the theory. Methodological verification also showed that there were different linear relationships in the range of 1.0E-10-1.0E-1 mg/mL and 0.5-10 mg/mL with LOD = 2.233E-11 mg/mL and LOQ = 7.444E-11 mg/mL. The excellent selectivity and specificity of the sensor were demonstrated and the sensor could be stored in 1X PBS (0.01 M) at 4 ? for one week. Repeatability and intermediate precision were measured, and the RSD remained below 5%. In addition, the sensor could be reused up to three times without affecting the results of the measurements. The results of application showed that the sensor had a more accurate response value in 1% of plasma matrix. Compared with the detection results of ELISA kit method, the sensor had the advantages of wider detection range, shorter detection time, higher accuracy, simple operation and low cost, which indicated that the sensor had a certain practicability and clinical translational application capability. This study also provided a new idea and method for the detection of other high molecular weight biomarkers in complex biological samples. (C) 2022 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available