3.8 Article

In Vitro Evaluation of Miniaturized Amperometric Enzyme Sensor Based on the Direct Electron Transfer Principle for Continuous Glucose Monitoring

Journal

JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY
Volume 16, Issue 5, Pages 1101-1106

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/19322968211070614

Keywords

FADGDH; direct electron transfer (DET); third-generation glucose sensor; continuous glucose monitoring (CGM)

Ask authors/readers for more resources

In this study, a miniaturized integrated electrode combined with DET-type FADGDH enzyme was successfully developed for continuous glucose monitoring. The sensor showed a linear response to glucose concentration up to 500 mg/dL over an 11-day continuous measurement, and its performance was not significantly affected by acetaminophen and oxygen partial pressure.
Background:The bacterial derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase (FADGDH) is the most promising enzyme for the third-generation principle-based enzyme sensor for continuous glucose monitoring (CGM). Due to the ability of the enzyme to transfer electrons directly to the electrode, recognized as direct electron transfer (DET)-type FADGDH, although no investigation has been reported about DET-type FADGDH employed on a miniaturized integrated electrode. Methods:The miniaturized integrated electrode was formed by sputtering gold (Au) onto a flexible film with 0.1 mm in thickness and divided into 3 parts. After an insulation layer was laminated, 3 openings for a working electrode, a counter electrode and a reference electrode were formed by dry etching. A reagent mix containing 1.2 x 10(-4) Unit of DET-type FADGDH and carbon particles was deposited. The long-term stability of sensor was evaluated by continuous operation, and its performance was also evaluated in the presence of acetaminophen and the change in oxygen partial pressure (pO(2)) level. Results:The amperometric response of the sensor showed a linear response to glucose concentration up to 500 mg/dL without significant change of the response over an 11-day continuous measurement. Moreover, the effect of acetaminophen and pO(2) on the response were negligible. Conclusions:These results indicate the superb potential of the DET-type FADGDH-based sensor with the combination of a miniaturized integrated electrode. Thus, the described miniaturized DET-type glucose sensor for CGM will be a promising tool for effective glycemic control. This will be further investigated using an in vivo study.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available