3.9 Article

Cost-Utility Analysis of a Latanoprost Cationic Emulsion (STN1013001) versus Other Latanoprost in the Treatment of Open-Angle Glaucoma or Ocular Hypertension and Concomitant Ocular Surface Disease in Germany

Journal

CLINICAL OPHTHALMOLOGY
Volume 16, Issue -, Pages 323-337

Publisher

DOVE MEDICAL PRESS LTD
DOI: 10.2147/OPTH.S351013

Keywords

open-angle glaucoma; ocular surface disease; STN1013001; latanoprost; cost-utility analysis; Germany

Categories

Funding

  1. Santen GmbH, Munchen, Germany

Ask authors/readers for more resources

This study aimed to estimate the cost-utility and economic value of STN1013001, a latanoprost cationic emulsion, compared to other latanoprost formulations in patients with open-angle glaucoma or ocular hypertension and concomitant ocular surface disease in Germany. The results showed that STN1013001 was more cost-effective and produced more quality-adjusted life years (QALYs) compared to latanoprost.
Purpose: This study aimed to estimate the cost-utility and economic value of STN1013001, a latanoprost cationic emulsion vs other latanoprost formulations (henceforth latanoprost) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT) and concomitant ocular surface disease (OSD) in Germany. Methods: An early 5-year Markov model-supported cost-utility analysis was performed to estimate costs, quality-adjusted life years (QALYs) and life-years saved (LYS) for STN1013001 vs latanoprost from the German health system perspective. The model included seven mutually exclusive health states and adopted a 1-year cycle length. The model was populated with pooled data derived, by means of a questionnaire, from a convenience sample of five German glaucoma specialists. Remaining data were derived from published sources. Data provided by the ophthalmologists included annual treatment adherence probabilities, utility values and resource utilization. The half-cycle correction as well as a discount rate of 3.0% per year were applied to costs (expressed in (sic)2020), life-year saved (LYS) and QALYs. The incremental cost-utility ratio (ICUR) was contrasted against the informal willingness-to-pay (WTP) threshold for incremental LYS saved or QALY gained ((sic)30,000) proposed for Germany. One-way and probabilistic sensitivity analyses (OWSA; PSA) tested the robustness of the base case ICUR. Results: Over the 5-year time horizon, STN1013001 strongly dominates latanoprost as it is less costly ((sic)1003.65 vs (sic)1145.37; -12.37%) and produces more QALYs (2.612 vs 2.365; +10.44%) per notional patient. Baseline findings were robust against all the variations included in OWSA. PSA shows that STN1013001 has a 100% probability of being cost-effective vs Latanoprost at each WTP threshold for incremental QALY gained. Conclusion: Once on the market, STN1013001 will provide a cost-effective and possibly strongly dominant therapy vs latanoprost for OAG/OHT+OSD patients from a German health system perspective. Future empirical research should confirm these findings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available