4.4 Article

Validated Modernized Assay for Foscarnet in Pharmaceutical Formulations Using Suppressed Ion Chromatography Developed through a Quality by Design Approach

Journal

SEPARATIONS
Volume 8, Issue 11, Pages -

Publisher

MDPI
DOI: 10.3390/separations8110209

Keywords

design of experiments; foscarnet; method development; monograph modernization; pharmaceutical quality control; suppressed ion chromatography; validation; quality by design

Ask authors/readers for more resources

Inspired by the USP monograph modernization initiative, a quality by design approach incorporating design of experiments and multivariate data analysis was used to develop and validate an assay for foscarnet sodium injection solution. The assay, based on ion chromatography with suppressed conductivity detection, was successfully validated according to ICH guidelines, showing a wide linear range and high repeatability. A multivariate assessment revealed the assay was robust and easily transferable between laboratories, even when using different liquid chromatography instrument types.
Inspired by the United States Pharmacopoeia (USP) monograph modernization initiative, we developed and validated an assay for foscarnet sodium injection solution ( foscavir ), following quality by design (QbD) principles, incorporating design of experiments (DoE) and multivariate data analysis to establish the design space and robust setpoint of the method. The resulting analytical procedure was based on ion chromatography (IC) with suppressed conductivity detection, employing an isocratic carbonate-bicarbonate eluent system. The assay was successfully validated at the robust setpoint conditions, according to the guidelines established by the International Council for Harmonization (ICH). The linear range stretched at least from 5 to 100 mg/L with high repeatability (relative standard deviation, RSD & LE; 0.3%) both at the target concentration (60 mg/L) and at 50% and 150% from this level. Special attention was given to establish a rugged assay that would be easily transferable between laboratories, and the recorded recoveries of 98.2-100.5% for both the formulated drug product and the drug substance during intermediate precision evaluation at different analysis situations indicated that this mission was accomplished. A multivariate assessment of intermediate precision data acquired using an experimental design scheme revealed that the assay was not adversely affected by any of the situation variables, including the use of different liquid chromatography instrument types, regardless of if they were constructed from inert materials or stainless steel that had been passivated, even though such problems have been reported in several previous methods for analysis of foscarnet.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available