Sensors to the Diagnostic Assessment of Anticancer and Antimicrobial Therapies Effectiveness by Drugs a with Pyrazine Scaffold

Journal

CHEMOSENSORS
Volume 10, Issue 1, Pages -

Publisher

MDPI
DOI: 10.3390/chemosensors10010024

Keywords

cyclic voltammetry; electropolymerization; pyrazine derivatives; glassy carbon electrode

Funding

  1. National Science Center (NCN) [2019/03/X/ST4/00038]
  2. [531-T120-D846-21]

Ask authors/readers for more resources

Researchers are developing a universal method to detect pyrazine derivatives in body fluids in order to prevent side effects. By electropolymerizing GCE surfaces, three types of modified electrodes were prepared and used as chemosensors for four pyrazine drugs in stoichiometric tests, providing detailed analysis and comparison.
Treatment with pyrazine derivatives-antituberculosis pyrazinamide (PZA), anticancer bortezomib (BZM), and antifungal pyrazine-2-amidoxime (PAOX) and pyrazine-2-thiocarboxamide (PTCA)-is associated with side effects, as observed in the case of other therapeutic drugs. To prevent the side effects of pyrazine derivatives, researchers are working to develop a universal method that will detect these compounds in body fluids. There is a lack of literature data about voltammetric measurements with poly-L-amino acid-modified GCEs surfaces. The available reports describe the application of various modifications of these electrodes for the detection of different active substances of drugs; however, they do not indicate one particular method for the detection of drugs with a pyrazine skeleton. This research aimed to prepare three types of glassy carbon electrodes (GCEs) with modified surfaces by electropolymerization using 1, 10, and 100 mM solutions of L-glycine (Gly), L-alanine (Ala), L-lysine (Lys), respectively. The poly-amino acid coatings applied on GCE surfaces were analyzed in detail under a three-dimensional (3D) microscope and were used as chemosensors of four pyrazine drugs in stoichiometric tests. The results were compared with the measurements made on an unmodified GCE. To obtain reliable results, the linearity of measurements was also verified in the concentration gradient and appropriate scanning speed was chosen to achieve the most accurate measurements.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available