4.7 Article

Optimisation of sacrificial anode cathodic protection system in chloride-contaminated reinforced concrete structure

Journal

JOURNAL OF BUILDING ENGINEERING
Volume 45, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.jobe.2021.103515

Keywords

Sacrificial anode cathodic protection (SACP); Steel corrosion; Reinforced concrete structure; Optimisation; Efficacy and efficiency

Funding

  1. Natural Science Foundation of China [51778566, 51638013]
  2. Natural Science Foundation of Zhejiang Province [LR21E080003]
  3. Ningbo 2025 Science and Technology Major Project [2020Z035]

Ask authors/readers for more resources

Research has shown that halving the anode spacing in an SACP system can better inhibit corrosion current, while increasing anode size has less significant effects. Additionally, a decrease in corrosion current is accompanied by a substantial increase in cathodic current, leading to an increase in anode consumption.
For chloride-contaminated reinforced concrete (RC) structures, sacrificial anode cathodic protection (SACP) is an effective method to control steel corrosion. However, some adverse phenomenon, such as insufficient protection current or excessive anode consumption, might affect system operation. The motivation of this work is to optimize SACP systems by generating optimal tradeoff between its efficacy and efficiency: 1) maximizing the steel corrosion current reduction; and 2) minimizing the anode mass consumption. In this study, five SACP systems in chloride-contaminated beam were simulated to investigate the influence of anode arrangement on the steel corrosion current reduction and anode consumption. The result reveals that halving the anode spacing has better improvement on corrosion current inhibition compared to doubling anode size. Simultaneously, it was found that corrosion current reduction was accompanied by significant increase in the cathodic current, and this increment of cathodic current leads to more than 50% additional anode consumption. Based on a comprehensive evaluation, in an SACP system, when the current supplied by anode corrosion is 5.0-7.5 times steel corrosion current, the SACP system efficacy and efficiency can be balanced.