4.6 Article

Conditional Covariances for the Signal Lag Measurements in Fluoroscopic Imaging

Journal

DIAGNOSTICS
Volume 12, Issue 1, Pages -

Publisher

MDPI
DOI: 10.3390/diagnostics12010087

Keywords

conditional covariance; fluoroscopic imaging; lag correction factor; nonuniform temporal gain; upper-lower correction

Funding

  1. National Research Foundation of Korea (NRF) - Korean government (MISP) [2020R1A2C1009895]
  2. Hankuk University of Foreign Studies Research Fund of 2021
  3. National Research Foundation of Korea [2020R1A2C1009895] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

This paper proposes a simple scheme to alleviate the nonuniform temporal gain (NTG) problem in fluoroscopic imaging for accurately and efficiently measuring the detector lag correction factor (LCF). By using conditional covariance to calculate correlation coefficients, the proposed approach can obtain accurate LCF values even under the NTG environment without any preprocessing scheme.
In fluoroscopic imaging, we can acquire X-ray image sequences using a flat-panel dynamic detector. However, lag signals from previous frames are added to the subsequently acquired images and produce lag artifacts. The lag signals also inflate the measured noise power spectrum (NPS) of a detector. In order to correct the measured NPS, the lag correction factor (LCF) is generally used. However, the nonuniform temporal gain (NTG), which is from inconsistent X-ray sources and readout circuits, can significantly distort the LCF measurements. In this paper, we propose a simple scheme to alleviate the NTG problem in order to accurately and efficiently measure the detector LCF. We first theoretically analyze the effects of NTG, especially on the correlation-based LCF measurement methods, where calculating the correlation coefficients are required. In order to remove the biases due to NTG, a notion of conditional covariance is considered for unbiased estimates of the correlation coefficients. Experiments using practical X-ray images acquired from a dynamic detector were conducted. The proposed approach could yield accurate LCF values similarly to the current approaches of the direct and U-L corrections with a low computational complexity. By calculating the correlation coefficients based on conditional covariance, we could obtain accurate LCF values even under the NTG environment. This approach does not require any preprocessing scheme of the direct or U-L correction and can provide further accurate LCF values than the method of IEC62220-1-3 does.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available