4.6 Article

Impact of integrating large-scale DFIG-based wind energy conversion system on the voltage stability of weak national grids: A case study of the Nigerian power grid

Journal

ENERGY REPORTS
Volume 7, Issue -, Pages 654-666

Publisher

ELSEVIER
DOI: 10.1016/j.egyr.2021.01.025

Keywords

Active power margin; DFIG; Reactive power margin; Voltage stability; Wind energy conversion system

Categories

Funding

  1. African Union Commission on the platform of Pan African University Scholarship

Ask authors/readers for more resources

This study investigates the impact of integrating large-scale DFIG-based WECS on the voltage stability of the Nigerian power grid, demonstrating the effectiveness of DFIG-based WECS in mitigating overvoltage issues while optimizing system stability. The optimal DFIG-based WECS penetration level that meets voltage criteria and system equipment loading requirements is found to be 35%, showing the potential of DFIG-based WECS as a viable solution for improving voltage stability in a weak national grid.
This paper investigates the impact of integrating large-scale Doubly-Fed Induction Generator (DFIG)based wind energy conversion system (WECS) on the voltage stability of the 52-bus, 330 kV Nigerian power grid. Indices derived from Active Power-Voltage (PV) and Reactive Power-Voltage (QV) analyses have been utilized to determine the voltage stability limits in terms of the maximum active power margin (APM) and minimum reactive power margin (RPM) of the system with the associated critical voltage-reactive power ratio (CVQR) of the system buses. Simulations have been done in DIgSILENT PowerFactory and the results analysed using MATLAB. This work also demonstrates the effectiveness of DFIG-based WECS in mitigating the overvoltage issues in the Northern region by ensuring that all bus voltages are within the acceptable limits of 1.0 +/- 0.05 p.u. The results show that the optimal DFIG-based WECS penetration level (PL) that satisfies a bus voltage criterion of 1.0 +/- 0.05p.u with the APM and CVQR not falling below their respective base case values and the loading of all critical power system equipment not exceeding 80% is 35%. Therefore, this work has demonstrated the possibilities of large-scale DFIG-based WECS as a viable solution for voltage stability improvement of a weak National grid while meeting the increasing energy demand. (C) 2021 The Author(s). Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available