4.6 Article

Physically Tailoring Ion Fluxes by Introducing Foamlike Structures into Polymeric Membranes of Solid Contact Ion-Selective Electrodes

Journal

ACS SENSORS
Volume 6, Issue 10, Pages 3667-3676

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acssensors.1c01413

Keywords

ion-selective electrode; potential stability; potential reproducibility; membrane modification; ion fluxes

Funding

  1. Economic Development Board (EDB) of Singapore's Industrial Postgraduate Program
  2. NEWRI (Nanyang Technological University)
  3. Singapore's Economic Development Board (EDB)
  4. Robert Bosch SEA

Ask authors/readers for more resources

Foamlike structures introduced into ion-selective membranes can physically tailor the transport of ions, reducing interference and improving the reproducibility of sensor potentials. This method, linked to temperature-controlled membrane deposition, shows promise for enhancing the performance of solid contact ion-selective electrodes based on polymeric membranes.
Transmembrane ion fluxes have earlier been identified as a source of potential instability in solid contact ion-selective electrodes (SC-ISEs). In this work, foamlike structures were intentionally introduced into a potassium-sensitive plasticized poly(vinyl chloride) ion-selective membrane (ISM) near the membrane vertical bar solid contact interface by controlling the temperature during membrane deposition. Foamlike structures in the ISM were shown to be effective at physically tailoring the transport of ions in the ion-selective membrane, greatly reducing the flux of interfering ions from the sample to the membrane vertical bar solid contact interface. The drifts during a conventional water layer test were hence able to be greatly mitigated, even with SC-ISEs incorporating a relatively hydrophilic poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) solid contact. In solutions with a high background concentration of interfering ions, equilibrated ion-selective electrodes with foamlike membranes were able to reproduce their initial potentials within 0.6 mV uncertainty (n = 3) from 0 to 18 h. This was achieved despite sensor exposure to solutions exceeding the selectivity limit of the ISEs in 3 h intervals, allowing improvement of the potential reproducibility of the sensors. Since the introduction of foamlike structures into ISM is linked to temperature-controlled membrane deposition, it is envisaged that the method is generally applicable to all solid contact ion-selective electrodes that are based on polymeric membranes and require membrane deposition from the cocktail solution.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available