In this study, a new optical pH sensor based on a polyelectrolyte membrane was developed for rapid and accurate measurement of fish freshness. Through trial-and-error investigation and optimization, a sensor with good reproducibility and stable response was successfully fabricated. The sensor was capable of measuring pH changes on fish skin at different temperatures.
Considering the significance of its demand around the world, the accurate determination of fish freshness with a simple and rapid procedure has become an interesting issue for the fishing industry. Hence, we aimed to fabricate a new optical pH sensor based on a polyelectrolyte (PEC) membrane of pectin-chitosan and the active material chromoionophore ETH 5294. A trial-and-error investigation of the polymer compositions revealed that the optimum ratio of pectin to chitosan was 3:7. With an optimum wavelength region (lambda) at 610 nm, the constructed sensor was capable of stable responses after 5 min exposure to phosphate-buffered solution. Furthermore, the obtained sensor achieved optimum sensitivity when the PBS concentration was 0.1 M, while the relative standard deviation values ranged from 2.07 to 2.34%, suggesting good reproducibility. Further investigation revealed that the sensor experienced decreased absorbance of 16.67-18.68% after 25 days of storage. Employing the optimum conditions stated previously, the sensor was tested to monitor fish freshness in samples that were stored at 4 degrees C and ambient temperature. The results suggested that the newly fabricated optical sensor could measure pH changes on fish skin after 25 h storage at room temperature (pH 6.37, 8.91 and 11.02, respectively) and 4 degrees C (pH 6.8, 7.31 and 7.92, respectively).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available